Maintenance; Maintenance Activities; Important Information Regarding The Refrigerant Used; Troubleshooting - Rotex RKHBRD011ABV1 Manuel D'utilisation

Masquer les pouces Voir aussi pour RKHBRD011ABV1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
M
AINTENANCE

Maintenance activities

In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals, preferably yearly. This maintenance should be
carried out by your local Rotex technician (see installation manual).
The only maintenance which may be required by the operator is:
keeping the remote controller clean by means of a soft damp
cloth,
checking if the water pressure indicated on the manometer is
above 1 bar.
If the supply cord is damaged, it must be replaced by the
manufacturer, its agent or similar qualified persons in order
to avoid hazards.
During longer periods of standstill, e.g. during summer with
a heating only application, it is very important NOT TO
SWITCH OFF THE POWER SUPPLY towards the unit.
Switching off the power supply stops the automatic
repetitive movement of the pump in order to prevent it from
getting jammed.

Important information regarding the refrigerant used

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
Refrigerant type:
R134a
(1)
GWP
value:
1300
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
Operation manual
18
T
ROUBLESHOOTING
The guidelines below might help to solve your problem. If you cannot
solve the problem, consult your installer.
P
OSSIBLE CAUSES
No readings on the remote controller
(blank display)
One of the error codes appears
The schedule timer does work but
the programmed actions are
executed at the wrong time
(e.g. 1 hour too late or too early)
The domestic hot water schedule
timer is programmed but does not
work.
Capacity shortage
D
ISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
Your product is marked with this symbol. This means that
electrical and electronic products shall not be mixed with
unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.
Units must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed off
correctly, you will help to prevent potential negative consequences for
the environment and human health. Please contact the installer or
local authority for more information.
Indoor unit for air to water heat pump system and options
C
ORRECTIVE ACTIONS
• Check if the mains power is still
connected to your installation.
• The benefit kWh rate power supply is
active (see installation manual).
Consult your local dealer.
Refer to the installation manual for a
detailed list of error codes.
Check if the clock and the day of the
week are set correctly, correct if
necessary.
In case the pr icon is not displayed,
push the pr button to enable the
schedule timer.
Consult your local dealer.
RKHBRD011~016ABV1+Y1
4PW61219-1

Publicité

Table des Matières
loading

Table des Matières