Napoleon Ascent Séries Manuel D'installation page 58

Linéaire. modèles de gaz naturel, modèles de propane. pour usage intérieur seulement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

troubleshooting
EN
symptom
Motor is turning,
frequent beeping
occurs.
Lights or blower
won't function (if
equipped).
Flames are very
aggressive.
Appliance won't per-
form any functions.
The following applies specifi cally to the SIT system only:
Pilot will not light.
Makes no noise with
no spark at pilot
burner. (Lights and
blower operate, if
f i r e - p a r t s . c o m
equipped).
note:
Starting from off, press the on button on the transmitter. Approximately 4 seconds on/off button is pressed, the ignition
board will start the spark. The fi rst try for ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi cation),
the board will stop sparking for approximately 35 seconds. After the wait time, the board will start the second try for ignition
by sparking for approximately 60 seconds. If there is still no positive ignition, the board will go into lock out.
58
W415-1705 / G / 03.21.19
problem
Receiver batteries low.
Control module switch in
wrong position.
COM switch is unplugged.
Door is ajar.
Venting action is too great.
No power to the system.
Receiver switch in wrong
position (if equipped).
Transmitter isn't operational.
Ignition box has been locked
out.
test solution
-
Replace batteries.
-
Verify ON/OFF switch is in the "I" position which denotes on.
-
Verify "COM" switch is plugged into the front of the control
module.
-
Ensure door is secured properly.
-
Check to ensure venting is properly sealed or restrict vent
exit with restrictor plate. (Not available in all appliances).
-
Check breaker to verify it's in the "on" position.
-
Verify that the 3 position switch on the receiver is in the
remote position (middle).
-
Check battery power and battery orientation.
Choose one of the 3 methods below to reset the system.
1.
To reset ignition box when locked out. Turn off power supply
and remove batteries (if used) from the back up battery pack.
2.
To reset the DFC Board when the board goes into a lock
out condition and the LED is blinking 3 times using the
transmitter on/off button:
Step 1: Turn the system off by pressing the on/off
button to turn the system off.
Step 2: After approximately 2 seconds press the on/
off button on the transmitter again. The DFC Board will
reset and the ignition sequence will start again.
3.
To reset the DFC Board when the board goes into a lock out
condition and the LED is blinking 3 times by cycling fl ame:
Step 1: In the manual fl ame control mode, use the down
arrow button to reduce the fl ame to off, indicated by the
word OFF displayed on the transmitter LCD screen.
Step 2: Wait approximately 2 seconds and press the up
arrow button, the ignition sequence will start.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ascent bl36nte-1Ascent bl46nteAscent bl36pte-1Ascent bl46pte

Table des Matières