Napoleon Ascent Séries Manuel D'installation page 40

Linéaire. modèles de gaz naturel, modèles de propane. pour usage intérieur seulement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

fi nish framing
EN
10.3 minimum clearance to combustible enclosures
note:
Vent Sections
When passing through a wall, use fi restop spacer W010-4404 (supplied).
When passing through a ceiling, use fi restop spacer W500-0096 (not supplied).
Center of
vent pipe
56"
(142.2cm)
f i r e - p a r t s . c o m
ceiling
(min.)
46"
(116.8cm)*
27 1/2"
(69.9cm)
0" to bottom of the
note:
The vent shield is telescopic and
must be adjusted to shield the
full depth of the combustible wall
penetration.
40
W415-1705 / G / 03.21.19
3" [76.2mm] minimum all sides for vertical venting.
Vent shield
(Not required for BL36-1)
Top of
combustible
opening
14"
Top of
(35.6cm)
appliance
opening
Non-combustible
material
Combustible
material
appliance
Non-combustible
Combustible
6 1/2"
**
(16.5cm)
(76.2mm)
3"
(76.2mm)
(25.4mm)
bottom
1"
(25.4mm)
* See "venting requirements" and "venting installation" sections.
** Clearances within the enclosure may be higher, see
"minimum framing dimensions" section.
3"
0" if non-combustible finishing
top
is used such as brick and stone.
1"(25.4mm)
to vent sides
1"
0" to back standoffs
0" to side standoffs