Handicare SIMPLICITY Manuel D'installation page 30

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 116
Appendix 3
Code:
d
Description:
The main power relay is welded closed.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
F
F
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
H
H
Description:
The main power relay is closed early.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
L
L
Description:
Telephone fault finding action:
Check client understands loading limits.
Send engineer if persistent fault.
On site fault finding action:
Check motor and track for obstructions.
30 HANDICARE SIMPLICITY INSTALLATION MANUAL
Meaning:
Relay not open (stopped).
Meaning:
Brake semi-conductor failed.
Meaning:
Relay not open (Pre delay).
Meaning:
Current limit exceeded.
Code:
E
E
Description:
The main power relay did not close.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check battery voltage and replace if necessary,
otherwise replace main board.
Code:
g
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check brake.
Code:
L
J
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace hinge interlock roller switch.
Code:
n
Description:
Telephone fault finding action:
Send engineer if permanently showing.
On site fault finding action:
Check reed switches and dipswitch settings.
Check battery voltage.
Meaning:
Relay not closed.
Meaning:
Brake not connected.
Meaning:
Hinge interlock switch error.
Meaning:
Half speed.

Publicité

Table des Matières
loading

Table des Matières