SANITIZING
Whenever the machine has remained unused for
some days after been cleaned and sanitized as
described in the chapter 10, the sanitizing
procedures described below must be performed
just prior to start-up the machine.
- Remove the main cover and the secondary
one.
- Pour sanitizing solution into the bowl carefully
following the manufacturer prescriptions.
- After restoring the main cover, switch on the
machine and let the auger rotating (all control
board LED switched off) leaving the sanitizing
solution for the time specified by its producer.
IMPORTANT
Never let the sanitizer inside the bowl
longer than the producer prescriptions.
- Drain the solution by opening the plunger to
allow the bowl to empty. Open and close the
plunger at least 10 times during draining to
sanitize the product way out area also.
- Thoroughly rinse repeating these operations
with clean water instead of sanitizer solution.
- Now the machine is ready to be used.
8. WARNINGS
- Anytime that you replace the grasp container
on the plate, make sure that the probe (K)
touches the bottom of the grasp container
perfectly (see fig. 14).
Fig. 14