To avoid electrical shock or contact with
moving parts, before proceeding with the
disassembling operations, make sure all
switches are in "OFF" position and that the
main power supply is disconnected.
- Turn off the machine with switch (B) (see fig.
4) and unplug it at the mains.
®
- Bring KAY-5
Sanitizer/Cleaner with a 100ppm
dilution (1 Oz packet of KAY-5
water) (the sanitizing product shall comply with
40 CFR §180.940).

!IMPORTANT!

The type and concentration of sanitizing
agent shall comply with 40 CFR §180.940
!IMPORTANT!
Carefully follow the instructions of the
sanitizer manufacturer with regard to
timing and method of use.
- Wash and sanitize your hands and forearms
otherwise use clean and sanitized gloves.
- Remove the lid.
- Using two container holders, in order to avoid
burns hands, grasp container (A) and lift it
upwards. The container and mixer (E) will be
automatically released from their seat (see fig.
8).
- Cool the container (A) (by dipping it in cold
water, for example).
- Simultaneously press the two securing tabs
and lift the tap to extract it from its seat (see
fig.9).
- Disassemble the tap by keeping the body
pressed down and slipping the lever from its
seat (fig.10).
To prevent bacteria growth, remove all
O-rings when cleaning.
Failure to do so could create a health
Data di emissione: September, 2018
Caution
®
+2 ½ gallons of
Caution
hazard.
Revisione: 1
Fig. 8
Fig. 9
Fig. 10
Pag. : 22/40