Secure the stand

There are three methods for fixing the stand.
Securing with vacuum plate
Fixing with expander or anchor
Fixing with threaded rod, washer and lock nut
Securing with vacuum plate
WARNING! The vacuum plate must never be
!
used for ceiling or wall drilling. Careless or
incorrect use can result in serious, even
fatal injury.
If the vacuum plate is used, make sure the
support surface is not porous and can
loosen from the floor or the wall. Make sure
that the vacuum pump has sufficient power
to secure the vacuum plate.
Connect the vacuum pump to the quick coupling for
vacuum pressure on the base plate.
Place the bottom plate in the desired position.
Switch on the vacuum pump. A minimum pressure of 635
mm Hg (25 inch Hg) must be reached so that the base
plate seals tightly against the surface.
Fixing with expander or anchor
IMPORTANT! When drilling roofs, only expander or anchor
suitable for surfaces exposed to tensile forces should be
used.
Use only expander or anchor which is approved for current
application.
10 –
English

ASSEMBLY

Drill a hole for the expander/anchor at a distance of 347
mm (13.6") from the center of the hole.
Bolt down the base plate. Check carefully that the
expander is secured correctly.
The bottom plate can be adjusted to the surface by using
the leveling adjustment screws. Use the feed lever.
Fixing with threaded rod, washer and lock
nut
If the mounting surface is inadequate for drilling in roofs or
walls, the base plate can be fixed using a threaded rod, which
is mounted on the backside with a washer and lock nut.
Drilling in the ceiling
!

Adjust the column tilt

Loosen the locking screws for column tilt and set the desired
drill angle. Tighten the locking screws. Use the feed lever. The
column can be tilted 0-60°.
The angle indicator can be used for approximate adjustment.
If higher precision is required, alternative measuring methods
should be used.
WARNING! Use a water collector to avoid
water penetrating into the machine. The
machine must be covered with plastic or the
like in order to prevent water penetrating
into the machine, but do not cover the air
intakes and air outlets.