Operation e Maintenence
Operation
GB
1. The hood has several operating speeds.
For more efficient performance, use the lowest
suction level when there is only a small amount of
smoke or steam and the higher suction level when
there are large amounts of smoke and steam;
there is also an intermediate suction level, which
should be used when the amount of smoke and
steam produced by the cooking process is at a
normal level.
2. We recommend that the hood is switched on a
few minutes before the cooking process is
started, and that it is only switched off after all
the odours have been completely eliminated.
Push-button controls
The control panel includes:
·
1 "I\0" button to turn the motor on/off
·
3 "I" "II" "III", buttons to adjust the
motor speed (1st - 2nd - 3rd speed)
·
1 "
" button to turn the lighting on/off
Electric control panel:
1
2
1 - lights ON/OFF button
2 - motor ON/OFF button
3 - "speed level 2" activation button
4 - "speed level 3" activation button
5 - "speed level 4" activation button
Switching the motor on and off.
When button 2 is pressed, the motor will start
running at "speed level 1". To switch off the motor
while it is running at "speed level 1", press button 2
once; for a higher speed level, press button 2
twice.
Setting the automatic deactivation timer.
To set the automatic motor deactivation timer (10
minutes), press and hold the button corresponding to
the selected speed level for 2 seconds. The LED
corresponding to this button will flash.
Resetting the filter alarm.
After every 30 hours of operation, the filter alarm will
be activated. To reset it, press and hold button 4 for 5
seconds while the motor is switched off.
10
5
3
4
Touch Control Panel:
The hood features "Touch Control" buttons. They are
activated by lightly touching the symbol related to the
function you want to use.
7
8
1
2
3
1 - lights on/off button
2 - motor on/off button/timer deactivation
3 - "speed level 2" on button/timer deactivation
4 - "speed level 3" on button/timer deactivation
5 - "speed level 4"/"speed level 5" on button/timer
deactivation
6 - timer activation button
Switching the motor on and off
When button 2 is pressed, the motor will start running at
"speed level 1". To switch off the motor while it is running
at "speed level 1", press button 2 once; for a higher
speed level, press button 2 twice.
In "speed level 4" press button 5 to switch to "speed level
5".
Timer activation/deactivation automatic switching off
To activate the motor automatic switching off timer (10
minutes), press button 6. At the end of the time the
motor and lights will switch off. To deactivate the timer
press any speed button (buttons 2-3-4-5)
Indicator lights
- with the motor off indicator lights 7-8-9-10 are off
- at "speed level 1" indicator light 7 is on
- at "speed level 2" indicator lights 7-8 are on
- at "speed level 3" indicator lights 7-8-9 are on
- at "speed level 4" indicator lights 7-8-9-10 are on
- at "speed level 5" indicator lights 7-8-9 are on and 10 is
flashing
- the timer is shown by indicator light 7 flashing
Resetting the filter alarm
The filter alarm activates every 100 hours of operation,
the alarm is shown by the flashing of indicator lights 7-
8-9-10 for 10 seconds, each time the motor switches
off. To reset it, press button 6 three times.