Technical data
Voltage range
LEDs
Tolerance
Voltage detection
Polarity detection
Range detection
Response time
Frequency range
Automatic load (RCD/FI)
Internal base load
Peak current
ON time
Single-pole phase test
Voltage range
Frequency range
Continuity test
Resistance range
Testing current
Overvoltage protection
Indication of rotating eld direction
Voltage range (LEDs)
Frequency range
Measuring principle
Power supply
Power consumption
Operating temperature
Humidity
Overvoltage category
Pollution degree
Degree of protection
Weight
Test standards
Subject to technical alterations. 11.2012
AC-tiveMaster
12, 24, 36, 50, 120, 230,
400, 690 V AC/DC
± 12, 24, 36, 50, 120, 230,
400, 690 V AC/DC
-30% to 0% of the reading
Automatic
Entire range
Automatic
< 0.1 s, LED
50/60 Hz
Yes
Approx. 2.1 W at 600 V
1s < 0.2 A / Is (5 s) < 3.5 mA
ON time = 30 s/10 min.
100 to 690 V AC
50/60 Hz
< 300
5 A
690 V AC/DC
100 to 400 V
50/60 Hz
Two-pole with contact electrode
2x 1.5 Type AAA, LR03, alkaline
Max. 30 mA / approx. 250 mW
-10°C ... 55°C
Max. 85% relative air humidity
CAT II 1000 V
with protective cover:
CAT III - 1000 V / CAT IV 600 V
2
IP64
220 g
EN 61243-3; EN 61326