2. CONNECTION PRINCIPLE
The closed heater can be installed inserted into an existing fireplace or in a hearth inside an adapted casing. Combustion air can be connected (collar
Ø75) under or behind the hearth or taken from the room (not connected). In the event that the combustion air is not connected, the room has to have a
supply of air to feed combustion (combustion air). The hot air is expelled by the fan (optional turbine kit).
Hot air
Obligatory casing
1000 option
Convection air
INSERT
INSERT
The hot air comes out through the front of the appliance. Distribution
of hot air is prohibited. The flue collar has to be connected (Ø 180) to
a flue (see DTU 24.1)
Combustion air connected
at the bottom (example)
Hot air
Hot air
Hot air
Option casing 1000
Convection air
Combustion air
when not connected
HEARTH
HEARTH
The flue collar has to be connected (Ø 180) to a flue (see DTU 24.1)
The hot air comes out through the front of the appliance. Optionally,
hot air can be distributed using collars (Ø 125 or Ø 150). In this case,
hot air is expelled through the upper part of the hearth (Diagram with
the 3 combustion air supply possibilities).
Combustion air connected at
the bottom (example)