3M™ MicroTouch™ Display M1500SS User Guide
Figure 3 Disassembling the Yoke & Base for Arm Mounting
Countertop Base Mounting Option
Keyhole slots in the bottom of the base plate enable you to secure the unit to a desktop or
countertop. Use standard screws in the desktop or countertop and then slide the base
plate on for a secure fit.
Note: A full size template has been included in the back of this manual for your
convenience.
Figure 4 Keyhole Mounting Slots
Step 1 -- Unlock the yoke. With the unit laying face
down safely and securely on a nonabrasive surface,
remove the two screws connecting the top of the yoke.
Lift yoke and pull down to disengage tabs to remove.
Step 2 -- Remove the bottom two screws holding the
hinge cover in place. Remove the small hinge cover.
Step 3 -- Remove the inner four screws holding the
base to the display and gently remove the base.
3M Touch Systems, Inc. Proprietary Information
7