Télécharger Imprimer la page

Master BP 13 INOX Notice D'utilisation page 18

Chauffe-terrasse

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
GAS REQUIREMENTS
Use propane or butane gas only.
The pressure regulator and hose assembly to be used must
conform to local standard codes.
The installation must conform to local codes, or in the absence of
local codes, with the standard for the storage and handling of liquid
petroleum gases.
A dented, rusted or damaged propane tank may be hazardous and
should be checked by your tank supplier. Never use a propane tank
with a damaged valve connection.
The propane tank must be arranged to provide for vapor withdrawal
from the operating cylinder.
Never connect an unregulated propane tank to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to
shipment. A complete gas tightness check must be performed at the
installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater.
Make a soap solution of one part liquid detergent and one part
water. The soap solution can be applied with a spray bottle, brush
or rag. Soap bubbles will appear in case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF position.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking
fittings, then turn the gas supply on and recheck.
Never leak test while smoking.
OPERATION AND STORAGE
TO TURN ON THE HEATER
1.
Turn on the valve on the gas supply cylinder completely.
2.
Press and turn the variable control knob and hold for 30 seconds.
Chile holding down the variable control knob, Press the igniter buton
several times until the pilot flame lights. Release the variable control
knob after the pilot flame lights.
Note:
If a new tank has just been connected, please allow at least one
minute for the air in the gas pipeline to purge out through the pilot
hole.
When lighting the pilot flame make sure that the variable control
knob is continuously pressed down while pressing the igniter button.
Variable control knob can be released after the pilot flame lights.
Pilot flame can be watched and checked from the small round
window with sliding lid located at the bottom of the flame screen (to
the left or right side of the corner).
If the pilot flame does not light or it goes out, repeat step 3.
4.
After the pilot flame lights, turn the variable control knob to
maximum position and leave it there for 5 minutes or more before
turning the knob to desired temperarure position.
TO TURN OFF THE HEATER
1.
Turn the variable control knob to PILOT position.
2.
Press and turn the variable control knob to OFF position.
3.
Turn off the valve on the gas supply cylinder completely.
Variable control knob
Igniter
STORAGE
1.
Always close the gas valve of the gas cylinder after use or in case
of a disturbance.
2.
Remove the pressure controller and the hose.
3.
Check the tightness of the gas valve and for damage. If you suspect
a damage, have it changed by your gas dealer.
4.
Never store liquid gas cylinder in a sub-terrain or at places without
adequate air ventilation.
CLEANING AND CARE
Wipe off powder coated surfaces with soft, moist rag. Do not clean
heater with cleaners that are combustible or corrosive.
Remove debris from the burner to keep it clean and safe for use.
Cover the burner unit with the optional protective cover when the
heater is not in use.
ASSEMBLY PARTS
Tools needed:
Open end wrench 10 & 13 mm
Adjustable opening wrench (2) 20 cm long
Slip joint pliers 23 cm long
Philips screwdriver w/ medium blade
Spray bottle of soap solution for leakage test
Parts supplied:
Stand with LPG cylinder housing and 3 post brackets.
9 Cup Nuts (M6 mm), 9 Small Screws (M6 x 10 mm), 9 Small Flat
Washers (Ø 6 mm) for Reflector Assembly.
6 Large Bolts and Flange Nuts (M6) for Support Legs/Main Pole
Assembly.
3 Medium Bolts (M8 x 15 mm) for Support Legs/Stand Assembly.
3 Reflector Spacers and Wing Nuts, 9 Large Flat Washers for
Reflector and burner Assembly.
3 pcs ground fixer
6 pcs M6 x 10 mm ground fixer bolts & nuts
ASSEMBLY PROCEDURES (Appendix I)
STEP 1
1-1. Put the 3 pcs post brackets on each position on the base as shown
in the picture.
1-2. Use 3 Medium Bolts(M8x15) to join the post brackets and stand.
STEP 2
2-1. Put the post on the top of 3 pcs post brackets.
2-2. Use 6 Large Bolts and Flange Nuts (M6) to connect the post to the
3 pcs post brackets. Tighten the bolts and nuts.
STEP 3
Place the tank housing on the stand.
STEP 4
4-1. Remove the 4 bolts from the burner.
4-2. Put the gas hose through into the post.
4-3. Fix the burner unit to the post by the 4 bolts.
STEP 5
5-1. Check whether the connection of vertical post and burner are
assembled according to instructions, and all bolts and nuts are tightened.
5-2. Put 6 pcs Large Flat Washers on 3 Reflector Spacers.
STEP 6
Fasten the reflector with 3 pcs Large Flat Washers and 3 pcs Wing Nuts.
STEP 7
7-1. Bring up the tank housing and rest it on the post plate.
7-2. Connect the regulator to the gas tank and tighten it with adjustable
wrench.
7-3. Connect the end thread of inlet gas hose to the regulator.
7-4. Put LPG gas tank on the stand.
PARTS AND SPECIFICATIONS (Appendix II)
I.
Reflector
II.
Flame screen
III.
Burner base
IV.
Air admittance fence
V.
Gas valve controller
VI.
Base of control housing
VII.
Post
VIII.
Tank housing
IX.
Post bracket
X.
Stand

Publicité

loading