Display code
Problem
A search is performed for
the sensor
"Unlocking active leaf"
No error
A search is performed for
the sensor
"Unlocking passive leaf"
No error
A search is performed for
the sensor
"Locking" active leaf
No error
A search is performed for
the sensor "Locked"
No error
Programming mode
active
Lock does not unlock
electrically
No error
Capacity check
No error
The "unlocked" sensor
position is lost during
daytime release and the
motor runs briefly
No error
Bus error
Cause
y
y
Test run
y
y
y
y
Test run
y
y
y
y
Test run
y
y
y
y
Test run
y
y
y
y
Service plug not
y
y
removed or latchbolt
monitoring not
actuated longer than
5 s
y
y
Deadbolt at the active
y
y
leaf has been moved
to the locked position
(only B-2393x)
y
y
When the emergency
power backup system
B-54903-23-3-9
is connected, the
controller checks the
capacity on a daily
basis
y
y
Motor dips during
y
y
daytime release due
to heavy vibrations
and readjusts in the
unlocking direction
y
y
Communication error
y
y
between lock and
controller
Help
See point 6.5
Test run
Test run
Test run
Exit programming
mode
(see point 6.2)
Unlock manually
the active leaf
Check the closing
speed and door strike
at the door closer and
reduce if necessary,
providing it can still be
ensured that the door
leaf closes.
Otherwise no
remedial action is
required.
Check wiring
(BR-GN, BL-RT)
(see point 2.3)