Installation instructions
B-2193x | B-2393x
Motor-driven shoot-bolt lock for timber and steel doors
58
5.
Signalling
5.1
Display codes
In addition to the function indications at the relay outputs, the motor-driven lock reports the status
via a red 7-segment display in the upper area of the controller. In this case, only the current/last
status is displayed.
B-54900-01-2-8
These status reports provide information on the following incorrect operations:
Display code
Problem
Status OK
No error
Locked
No error
Init
No error
Driving
No error
Short-term release
No error
Daytime release
No error
Test run
No error
EN
Fig. 17: Display codes
Cause
y
y
Test run successfully
performed
y
y
Lock motor-driven to
initial position
y
y
Initialisation in
process
y
y
Controller
restarted
y
y
Motor is driving
y
y
Short-term release
activated
y
y
Signal on I1 or I2
y
y
Daytime
activated
y
y
Continuous signal on
I1 or I2
y
y
Controller is waiting
for signal for test run
(see point 6.5)
Help
y
y
Confirm with control
signal at I2 in order to
reach Status "L"
y
y
During installation: no
fault
y
y
During operation:
check voltage supply
(G2/V2)
If voltage OK, then
replace controller
y
y
Finish continuous
signal
y
y
Set control signal at I2
and perform test run
06.2019 | 22288S | Designed in Germany