Télécharger Imprimer la page

Leister MINIFLOOR Instructions D'utilisation page 19

Masquer les pouces Voir aussi pour MINIFLOOR:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Parameter settings
Set the required welding speed on the
MINIFLOOR potentiometer (7).
Adjust the required welding temperature and
– if available – the air volume setting on the
optional hot air hand tool (22).
For the hot air hand tool (22) settings, plea-
se observe the operating instructions of the
device in use.
Level
1
2
3
4
5
6
7
8
9
10
Work environment/Safety
The device should only be used in the open or in a well-ventilated area. Be careful not to burn the material during
welding.
Follow the safety precautions provided by the manufacturer for the material.
Prior to commissioning, check the power supply cord (1), the plug, and the extension cable for
electrical and mechanical damage. Use extension cables with protective conductors only!
The MINIFLOOR must not be used in areas with explosion and/or ignition hazards. Ensure
a stable position during work. The power supply cord (1) must be able to move freely and
must not hinder the user or third parties while working.
Place the MINIFLOOR on a horizontal, fi re-
proof support and ensure suffi cient distance
from fl ammable materials and explosive
gases!
Swivel the hot air hand tool (22) into the
parking position during interruptions or to
cool it down (see image below). To transport,
allow the device to cool and switch off the
main switch (6).
m/min
ft./min
0.4
1.3
0.9
2.9
1.3
4.3
1.7
5.6
2.3
7.5
2.7
8.9
3.1
10.1
3.5
11.5
4.0
13.1
4.3
14.1
7
6
22
22
1
19

Publicité

loading

Ce manuel est également adapté pour:

154.333154.334