If fume emission does persist, the following immediate actions should be taken:
(a) Open doors and windows to ventilate room.
(b) Let the fire out or eject and safely dispose of fuel from the appliance.
(c) Check for flue or chimney blockage, and clean if required.
(d) Do not attempt to relight the fire until the cause of the fume emission has been
identified and corrected. If necessary seek expert advice.
IMPORTANT - Warning Note!
Do not use an aerosol spray on or near the stove when it is alight.
IMPORTANT - Safety advice!
When using the stove in situations where children, aged and/or infirm persons are pres-
ent a fireguard must be used to prevent accidental contact with the stove. The fire-
guard should be manufactured in accordance with BS 8423:2002 (Replaces BS 6539).

Lighting and fuelling

NOTE
: If airsystem is connected, the valve must be open.
TIPS before firing up:
Open a door or window close to the wood burning stove.
If there is a "storm" in the stove coming from the chimney, it is advisable to place a
screwed-up piece of newspaper between the upper baffle plate and the chimney, set
the paper on fire, and wait until you hear a "rumbling" noise in the chimney.. This
means that there definitely is a draught in the chimney and you avoid smoke in the
room.
"Top-Down" lighting
Start by placing 3-4 pieces wood - approx. 1½-2 kiligram - in the bottom of the burn-
ing chamber.
Place approx. 1 kilogram of firewood, split into kindling sticks, and a couple of alcohol
briquettes or similar (1-2). Set the air damper to fully open position.
Light the fire and close the door (3), leaving the door ajar approx. 10-15 mm.
When the flames are clear - after approx. 10-15 min. - close the door completely(4).
Damper - see adjustment of air damper.
When the last flames are extinguished and there is a nice layer of embers (5) - add 2-3
pieces of wood.
Leave the door ajar (6) until the fire has a good hold close the door completely.
Damper - see adjustment of air damper.
After approx. 5 min. - or when the flames are clear and stable - close the damper
gradually.
Note!
Keep an eye on the stove when lighting.
During operation the door should always remain shut.