TROUBLESHOOTING
Maintenance work on electrical equipment must be entrusted to persons qualified to do
CAUSES
Completely off
Programming
Front panel
Electronic board
Connections
Control
Cooling unit
No air circulation
Ventilation vane
For all servicing operations in the power-source outside the points mentioned above :
450 /
450
STARMATIC A
R
such work (see chapter SAFETY INSTRUCTIONS).
FRONT PANEL PARTIALLY OR COMPLETELY OFF
GREEN STATUS LIGHT OFF WITHOUT REPORTING ERROR
GREEN STATUS LIGHT OFF AND WIRE FEED SAFETY ERROR
POWER SOURCE "ON" AND NO POWER
POWER SOURCE "ON" AND WATER SAFETY ERROR
POWER SOURCE "ON" AND VENTILATION SAFETY ERROR
CALL IN A SPECIALISED TECHNICIAN
REMEDIES
check fuse F1
check that the selected WIRE/GAS pair is valid
check that no key is being permanently held in
check fuse F3 on the wire-feed interface board
check the polarities of the power cable and the earth
lead
check the presence of the "ON" control if the no-load
voltage is null
if the cooling unit has already operated, check the
cooling liquid level and the absence of air bubbles in
the circuit
if it has not operated, check fuse F2 on the wire-feed
interface board
check that side panels are properly in place
check the cleanliness of the dust filter
check the mechanical operation of the ventilation
safety vane behind the filter
check fuse F1 on the wire-feed interface board
- 109