channel 2 is activated. OFF / No priority channel is activated.
The default priority channels are channel 9/AM (EMG1) and channel 19/
AM (EMG2).
See the EMG SET 1 and EMG SET 2 menus page 38 to
Note: Activating a priority channel prevents changing the modulation
mode (AM / FM / UK), scanning the channels or activating the
If the KEY BEEP function is activated, an error beep sounds. "EMG" and the
channel blink to indicate unauthorized handling. Turn the switch (11) to the
OFF position to use these functions.
12) CB/PA
CB
PA
Switch between
and
(Public Address) mode.
An external optional speaker can be connected to the unit to the PA.SP.
jack on the rear panel. (D). Turn the MIC GAIN knob (4) to adjust the
volume.
For details on operating in PA mode, see the PA SETTING menu on page
39.
13) MODE (AM/FM/FM UK)
Press MODE key (13) to
select
mode is displayed on LCD.
Your modulation mode has to correspond to the one of your correspondent.
-
Frequency Modulation / FM: for nearby communications on a flat open
field.
-
Amplitude Modulation / AM: communication on a field with relief and
obstacles at middle distance (the most used).
In U configuration only: The MODE key (13) allows to
CEPT frequency band. "UK" is displayed when the ENG frequency band
is selected. When the CEPT frequency band is selected, "UK" disappears
from the display (see table on page 57).
14) BARGRAPH
Indicates
the reception level and the emitted power level.
set
priority channels.
PA
the modulation mode: AM or FM. Selected
select
the ENG or
15) 6 PIN MICROPHONE PLUG
The plug is located on the front panel of the transceiver and makes the
setting of the equipment into the dashboard easier.
See Cabling Diagram page 60.
16) USB CHARGING SOCKET
mode.
The USB socket (16) can be used to charge smartphones, tablets or other
rechargeable devices with 5 V - 2.1 A.
17) PTT
Transmission key, press to
to
listen to
an incoming communication,
TOT (Time Out Timer)
PA
If the PTT switch (17) key is pressed for more than 5 minutes, the display starts
blinking and the transmission ends. A beep will sound until the PTT switch
(17) key is released.
18) UP/DN BUTTONS ON MICROPHONE ~ SCAN
UP/DN BUTTONS ON MICROPHONE
In normal use, press UP/DN buttons (18) on the microphone to
channel. UP to
increase
In MENU mode [press the PUSH knob (6) for about 3 seconds to activate this
mode (see § MENU page 37)], the UP or DN buttons (18) allows to
the menu to be set.
See ROTARY "PUSH" KNOB page 34.
SCAN
(long press)
Press and hold the UP or DN button (18) for ± 7 seconds or until a beep
sounds to activate the SCAN function. The dot between the two channel
digits flashes to indicate that the function is active.
The scanning stops as soon as there is a busy channel. The scanning auto-
matically starts 3 seconds after the end of the transmission and no key is
activated during 3 s. In
press the UP/DN buttons (18) on the microphone to change scan direction.
Press PTT switch (17) to exit SCAN. The dot between the two channel digits
disappears from LCD.
36
transmit
a message,
is displayed and release
disappears.
(short press)
and DN to
decrease
the channel.
mode, turn the PUSH rotary knob (6) or
SCANNING
change
the
select