Brief Description - Camille Bauer SIRAX SI 815-6 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Passive DC signal isolator SIRAX SI 815-6
Contents
1. Read first and then... ................................................ 12
2. Scope of supply ........................................................ 12
3. Brief description ........................................................ 12
4. Technical data ........................................................... 13
6. Electrical connections ............................................... 14
7. Mounting ................................................................... 14
8. Commissioning ......................................................... 15
9. Maintenance ............................................................. 15
10. Releasing the signal isolator ..................................... 15
11. Dimensional drawing ................................................. 15
1. Read first and then ...
The proper and safe operation of the device
assumes that the Operating Instructions are
read carefully and the safety warnings given
in the sections
5. Mechanical coding of the
plug-in module
6. Electrical connections
are observed.
The device should only be handled by appro-
priately trained personnel who are familiar
with it and authorised to work in electrical
installations.
Unauthorized repair or alteration of the unit
invalidates the warranty.
2. Scope of supply
Signal isolator (1) (incl. plugged sets of codes)
Order Code: Significance of the digits
815 - 6 x x x
1
Standard (non-Ex)
2
[EEx ia] IIC, outputs intrinsically safe
2
2 channels (interfaces)
0 Without FSK communication
2 With FSK communication
1 Coding comb (2)
(for coding the backplane SIRAX BP 902)
1 Type Examination Certificate (3), (for Ex version
devices only)
1 Operating Instructions (4) in three languages: German,
French, English
12
(4)
(1)
Betriebsanleitung
Passiver DC-Signaltrenner SIRAX SI 815-6
Mode d'emploi
Séparateur galvanique passif
SIRAX SI 815-6
Operating Instructions
Passive DC signal isolator SIRAX SI 815-6
SI 815-6 B d-f-
108 242
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Telefon +41 56 618 21 11
Telefax +41 56 618 24 58
e-mail: info@camillebauer.com
http://www.camillebauer.com
Fig. 1

3. Brief description

The signal isolator SIRAX SI 815 serves to electrically insulate
the 4...20 mA input circuit of a two-wire transmitter. It
performs two tasks at the same time. Firstly it provides
electrical insulation and secondly it conducts the power
supply needed for measurement to the two-wire transmitter
without injecting into the circuit itself. Thus the isolator does
not require an power supply connection itself.
Some versions of the SIRAX SI 815 are designed for FSK
communication. They are used in conjunction with "intelli-
gent" two-wire transmitter which are capable of dialogue and
operation according to the FSK principle and the HART or
user-specific protocol.
FSK
Digital signal
W
2-wire
transducer
G
T
+
X
A
mA
-
4...20 mA
O
Analogue signal
Power supply
Fig. 2. Block diagram.
(2)
(3)
06.97
Hand-held
terminal
Power pack
Z
LR
+
E
-
Power
supply
Receiver
4...20 mA

Publicité