Product Description; Circuit Diagram; Connection Terminals; Approvals And Markings - DOLD SAFEMASTER C UG 6970 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER C
Multifunctional Safety Module
UG 6970

Product Description

The multifunctional safety module UG 6970 provides protection of men
and machines by enabling and disabling a safety circuit. It is used together
with e-stop buttons, safety gates, light curtains with self testing (type 4)
to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and
productions machines with dangerous closing movements (type III C to
EN 574) and safety mats, edges and tape switches. Simply select 2 out of
6 safety functions on rotary switches - ready. This reduces divers types of
safety modules in stock and simplifies your disposition.

Circuit Diagram

13
14
23
24
A1+
A2
ST1
38
S11
S12
S21
S22
13
43
23
+
K1
K3
K1/K2
K2
K4
14
44
24
38
S31
S32
S41
S42
68
RES
GND
ST2
43
44
53
54

Connection Terminals

Terminal designation
A1 +
A2
13, 14, 23, 24,
43, 44, 53, 54
38, 68
GND
S11, S21, S31, S41
S12, S22, S32, S42,
ST1, ST2, RES
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
53
+
K3/K4
54
68
M10501_a
Signal description
DC 24 V
0 V
Forcibly guided NO contacts for
release circuit
Semiconductor monitoring output
Reference potential for
Semiconductor monitoring output
Control output
Control input
Your Advantage
• 2 independent, separately adjustable safety funcions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain
• Only one device, two safety functions at the same time
• Manual or auto start
• Protection against manipulation by sealable transparent cover
Features
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: 2 NO contacts per safety function
• 1 semiconductor output per safety function
• LED indicator for operation, safety function 1, 2 and failure
• As option with pluggable terminal blocks for easy exchange of devices
- With screw terminals
- Or with cage clamp terminals
• Width: 22.5 mm

Approvals and Markings

Application

For enable and interrupt a safety circuit in a safe way. It can be used to
protect people and machines in applications with e-stop buttons, safe-
ty gates, light curtains with selftesting (Type 4) acc. to IEC/EN 61496-1,
2-hand controls for presses as well as other production machinery with
dangerous closing action (Type III C to EN 574) and for safety mats, safety
edges and tape switches with a max. switching current of 15 mA.

Indicators

Green LED ON:
Red LED ERR:
Green LED K1/K2:
Green LED K3/K4:
17
Canada / USA
On, when supply connected
On, at internal error
Flashes at external error
On, when relay K1 and K2 energized
(safety function 1)
Flashes at external errors of
safety function 1
(see flashing codes)
On, when relay K3 and K4 energized
(safety function 2)
Flashes at external errors of
safety function 2
(see flashing codes)
UG 6970 / 08.07.19 en / 214A

Publicité

Table des Matières
loading

Table des Matières