Télécharger Imprimer la page

Metabo HPT NV 83A2 Manuel D'instructions Et De Sécurité page 13

Publicité

Les langues disponibles

Les langues disponibles

Nailer Side
Lubricator
3. Air hose
Compressed air supply hoses shall have a minimum
working pressure rating equal to or greater than the
pressure from the power source if a regulator fails, or
150 psi (10.4 bar 10.6 kgf/cm
4. Air consumption
Using the Air consumption table and the Air
compressor size formula, fi nd a correct compressor
size.
Air consumption table
Operating pressure
Air consumption
ft
/cycle
3
(Itr/cycle)
Air compressor size formula
Amount of air required
=number of Nailers
× average nails driven each minute per Nailer
× air consumption at given air pressure
× safety factor (always 1.2)
Example: 2 Nailers (NV83A2) operating at 100 psi
driving 30 nails per minute
Amount of air required
=2 × 30 × .084 (2.4) × 1.2
=6.0 CFM (ft
/min) (173 ltr/min)
3
After making the calculations as shown above, you
should fi nd a compressor providing 6.0 CFM of air
that is required.
LUBRICATION
It is important that the Nailer be properly lubricated.
Without proper lubrication, the Nailer will not work
properly and parts will wear prematurely.
○ Use metabo HPT pneumatic tool lubricant.
Regulator
Compressor Side
Filter
), whichever is greater.
2
psi
80
90
(bar)
(5.5)
(6.2)
(kgf/cm
)
(5.6)
(6.3)
2
.062
.073
NV83A2
(1.8)
(2.1)
.048
.061
NV65AC
(1.4)
(1.7)
.025
.030
NV50A1
(.71)
(.85)
Do not use detergent oil or additives. These lubricants
will harm the O-rings and other rubber parts. This will
cause the Nailer to malfunction.
○ Filter-regulator-lubricator units should always be
used.
Keep the lubricator fi lled with metabo HPT pneumatic
tool lubricant.
○ If a lubricator is not available, supply 5 – 10 drops of
metabo HPT pneumatic tool lubricant into the air plug
on the Nailer twice a day.
COLD WEATHER CARE
○ Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area until beginning the
work.
○ If the Nailer is already cold, bring it in a warm area
and allow the Nailer to warm up before use.
1 Reduce the air pressure to 64 psi (4.4 bar
4.5 kgf/cm
2 Remove all nails from the Nailer.
3 Connect the air hose and free-fi re (blank-fi re) the
Nailer.
The lowered air pressure will be enough to free-
100
fi re the Nailer.
(6.9)
Slow speed operation tends to warm up the
(7)
moving part.
.084
(2.4)
CAUTION
● Do not free-fi re the Nailer at high pressure.
.075
(2.1)
TESTING THE NAILER
.035
(.99)
● Never use Nailer unless push lever is
operating properly.
Before actually beginning the nailing work, test the Nailer
by using the checklist below. Conduct the tests in the
following order.
If abnormal operation occurs, stop using the Nailer
and contact a metabo HPT authorized service center
immediately.
).
2
DANGER
● Operators and others in work
area
MUST
wear
glasses with side shields
which conforms to ANSI Z87.1
specifi cations.
Ordinary eyeglasses do not
provide adequate protection.
WARNING
English
safety
13

Publicité

loading

Ce manuel est également adapté pour: