STEP THREE:
Connect TrueSTEAM to the Water Pipe
1
STEP FOUR:
Connect to the Water Drain
M29607
CAUTION: Scalding Hazard.
During operation, hot water may exit drain and can cause burns from scalding.
Make sure the hose is securely connected to the drain.
Before proceeding to Wiring:
I have confirmed minimum required circuit capacity
I have connected the water supply using cold water
I have installed the drain connection
TrueSTEAM Humidification System 69-2285EF—01
2
M29606
1
2
3
4
Connect one end of the remaining length of water
line to the backflow preventer. Apply a modest pull to
ensure a tight fit. See "Appendix F: Reverse Osmosis
Filter" on page 42 if using the Reverse Osmosis Filter.
Connect the other end of this line to the saddle valve
or T-fitting and manual shutoff valve.
Consult and follow local plumbing codes for drain
pipe size and maximum temperature requirement.
The ideal installation is directly to the main floor
drain using the rubber hose provided.
If direct floor drain access is not available,
"Appendix E: Advanced Draining" on page 41.
Connect the 1/2-inch drain hose provided to the drain
fitting on the bottom of the TrueSTEAM.
Use the hose clamp provided to secure the drain hose
to the barbed fitting.
Route the drain hose to the floor drain. The hose must
have a continuous downward slope.
Direct the hose outlet into the floor drain. Secure
the hose to reduce the risk of hot water pooling
or splashing.
see
11

Publicité

Chapitres

Table des Matières
loading

Table des Matières