How To Charge The Batteries With On-Board Charger - Clarke ENCORE S2426 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

How To Prepare the Machine For Operation
4.
Disconnect the battery pack connector from the control housing
connector. See figure 14A.
5.
Connect the DC connector on the charger to the battery pack
connector. See figure 14B.
6.
Connect the charger to a properly grounded single phase (3-
wire) wall receptacle having the input voltage, frequency, and
ampere capacity specified on the nameplate of the charger.
For more information on the use of the charger, read
the instructions supplied with the charger.

How To Charge The Batteries With On-Board Charger

WARNING:
Charging the batteries in an area without ad-
equate ventilation could result in an explosion.
To prevent an explosion, charge the batteries
only in an area with good ventilation.
WARNING:
Lead acid batteries generate gases which could
explode. Keep sparks and flames away from
batteries. NO SMOKING!
CAUTION:
See Charger Owner's Manual. All onboard
battery chargers are programmed for a
specific type battery. The charger may need
reprogramming to properly charge
replacement batteries different than the
originally equipped Clarke battery.
NOTE: Only replace batteries with the identical Clarke battery
pack as originally equipped. The correct Clarke battery part
number can be found on the Clarke battery label affixed to the top
of each battery.
If the replacement battery is a different Clarke battery, please
contact Clarke Technical Service, 1-800-356-7274, for
instructions.
If the replacement battery is not a Clarke battery, please contact
the charger manufacturer for instructions.
To charge the batteries with the on-board charger, follow this
procedure:
1.
Place the key switch is in the "OFF" position.
2.
Before charging the batteries, the battery compartment needs to be
vented. To vent compartment, tip up the recovery tank until it locks
in the open position (see figure 15). To close the tank, pull up on
the arm and then slowly lower the tank to the closed position.
CAUTION:
Before raising tank, be sure tank is empty.
WARNING:
Do not operate or perform maintenance on the
machine while the recovery tank is in the open
position. The tank can be accidentally bumped
and it may slam shut.
3.
Connect the battery charger AC cord located at the rear of the
machine to a 15 amp (min) 120V properly grounded wall recep-
tacle.
Clarke
®
Operator's Manual (EN) - Encore S2426 / L2426 / S2426 OBC / L2426 OBC
ENGLISH
EN
Figure 14A
Figure 14B
Figure 15
- 15 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Encore l2426Encore s2426 obcEncore l2426 obc

Table des Matières