CALIBRATION of the GAIN : Immerse the pH probe into the buffer solution (for ex. 4 pH).
Press the F button until the CA2 function – calibration function of Gain- will appear. Press
Enter to confirm the choice.
Wait until the measure is stable and then modify the reading by the buttons UP and DOWN
until the value of the buffer solution (in the ex. 4pH). Press Enter to confirm
SETPOINT: Press the F button until the Set function – set-point function- will appear. Press
Enter to confirm the choice. Modify the reading by pressing the UP and DOWN buttons until
the desired value. Press Enter to confirm the choice.
TYPE OF DOSING : Press the F button until the Typ function will appear. Press Enter to
confirm the choise. Press UP and DOWN buttons to visualise one of the next options:
- bAS : if you would like the dosing for pH values lower than the value of the set point.
- Acd: : if you would like the dosing for pH values higher than the value of the set point.
Press Enter to confirm the choice.
The pump starts to work (green led lights up).
4.5 EXAMPLES OF PROGRAMMATION
> SET POINT 7,4 pH Dosing for pH values higher than the set-point
After having calibrated the probe, choose the pH set-point and the value of Typ (type of
dosing).
Press the F button until the function Set – set-point function.
Press the Enter button to confirm the choice. Modify the reading pressing the UP and DOWN
buttons until the value of 7,4pH and then press Enter to confirm.
Press the F button until the function Typ – function of dosing will appear.
Press Enter to confirm the choice. Set the reading Acd by pressing the UP and DOWN buttons
and confirm by Enter. The green Led will light up and the pump will work.
> SET POINT 7,2 pH Dosing for pH values lower than the set-point
After having calibrated the probe, choose the pH set-point and the value of Typ (type of
dosing).
Press the F button until the function Set – set-point function.
Press the Enter button to confirm the choice. Modify the reading pressing the UP and DOWN
buttons until the value of 7,2pH and then press Enter to confirm.
Press the F button until the function Typ – function of dosing will appear.
Press Enter to confirm the choice. Set the reading bAS by pressing the UP and DOWN but-
tons and confirm by Enter. The green Led will light up and the pump will work.