Table of faults
Table. 2
Code
Fault
Possible cause
fault
No gas
A01
No burner ignition
Ignition/detection electrode fault
Defective gas valve
Ignition power too low
Electrode fault
Flame present signal with
A02
burner off
Card trouble
Heating sensor damaged
Over-temperature
toA03
protection trips
No water circulation in the system
Air in the system
Fume thermostat
Fume thermostat contact open
activated (after activation of
Wiring disconnected
F04
the fume thermostat, boiler
Flue not correctly sized or
operation is prevented for
obstructed
20 minutes)
Low pressure in the gas system
No flame after the ignition
A06
phase
Burner minimum pressure setting
Sensor damaged
F10
Delivery 1 sensor fault
Wiring shorted
Wiring disconnected
Sensor damaged
F11
Tap water sensor fault
Wiring shorted
Wiring disconnected
Sensor damaged
F14
Delivery 2 sensor fault
Wiring shorted
Wiring disconnected
Supply voltage under
F34
Electric mains trouble
170V.
F35
Irregular mains frequency
Electric mains trouble
Pressure too low
Incorrect system water
F37
pressure
Sensor damaged
Probe damaged or wiring shorted
F39
External sensor fault
Sensor disconnected after activat-
ing the sliding temperature
Incorrect system water
F40
Pressure too high
pressure
A41
Sensor positioning
Delivery sensor detached from pipe
F42
Heating sensor fault
Sensor damaged
No system H
F43
Exchanger protection trips.
Air in the system
System water pressure
F47
Wiring disconnected
sensor fault
F50
Modureg fault
Wiring disconnected
34
EN
Recommended cure
Check the regular gas flow to the
boiler and that the air has been
eliminated from the pipes
Check the wiring of the electrode
and that it is correctly positioned
and free of any deposits
Check and change the gas valve
Adjust the ignition power
Check the ionisation electrode
wiring
Check the card
Check the correct positioning and
operation of the heating sensor
Check the circulator
Vent the system
Check the thermostat
Check the wiring
Change the flue
Check the gas pressure
Check the pressures
Check the wiring or replace the
sensor
Check the wiring or replace the
sensor
Check the wiring or replace the
sensor
Check the electrical system
Check the electrical system
Fill the system
Check the sensor
Check the wiring or change the
sensor
Reconnect the external sensor or
disable the sliding temperature
Check the system
Check the safety valve
Check the expansion tank
Check the correct positioning and
operation of the heating sensor
Change the sensor
O circulation
Check the circulator
2
Vent the system
Check the wiring
Check the wiring
cod. 3540S840 - 02/2010 (Rev. 00)
DIVAtop HC
5. TECHNICAL DATA AND CHARACTERISTICS
5.1 General view and main components
126
78
278
81
20
21
22
95
10
209
fig. 22 - General view DIVAtop HC 24
78
278
81
20
21
22
95
10
209
fig. 23 - General view DIVAtop HC 32
7
Gas inlet
10
System delivery
11
System return
14
Safety valve
19
Combustion chamber
20
Burner assembly
21
Main nozzle
22
Burner
26
Combustion chamber insulation
27
Copper exchanger
32
Heating circulating pump
36
Automatic air vent
44
Gas valve
56
Expansion tank
74
System filling cock
78
Anti-backflow device
81
Ignition and detection electrode
95
Diverter valve
126
Fume thermostat
145
Pressure gauge
209
Hot water tank delivery
210
Hot water tank return
246
Pressure transducer
278
Double sensor (Safety + Heating)
56
27
19
26
14
36
246
145
44
7
210
74
11
32
126
56
27
19
26
14
36
246
145
44
7
210
74
11
32

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Divatop hc 32

Table des Matières