Cleaning
The instrument does not need any special care.
Dirt and deposits can be removed from the instrument by washing it with
cold water. A sponge can be used for wiping if necessary.
Abrasive cleaning implements (brushes etc.), cleaning agents and cleaning
solvents can destroy the dust and water filters.
Carefully dab dry the instrument using a cloth.
Maintenance
The maintenance intervals and measures specified in the Technical Handbook
as well as the specifications in the Instructions for Use/data sheets of the
® 2)
DrägerSensors
used must be carefully observed.
Repairs to the instrument may only be carried out by trained service personnel.
The instrument should be inspected and serviced once a year by suitably
qualified persons. Comparisons:
EN 60079-29-2 – Gas detectors - Selection, installation, use and
maintenance of detectors for flammable gases and oxygen
EN 45544-4 – Electrical apparatus used for the direct detection and direct
concentration measurement of toxic gases and vapours - Part 4: Guide for
selection, installation, use and maintenance
National regulations
Recommended calibration interval for measuring channels O
NO
and CO: 6 months.
2
Recommended calibration intervals for the measuring channel IR Ex/CO
months.
Calibration intervals of other gases: see Instructions for Use of the applicable
DrägerSensors.
See the Technical Manual for details of spare parts.
1)
The Technical Handbook and Instructions for Use/data sheets for the sensors used and the PC
software CC-Vision for Dräger X-am 5600 are available on the product page of the 
X-am 5600 at the following Internet address: www.draeger.com.
See also the supplied Instructions for Use and data sheets.
®
2)
DrägerSensor
is a registered trademark of Dräger.
24
CAUTION
, H
S, H
, SO
2
2
2
Storage
Dräger recommends storing the instrument in the charger module (order
no. 83 18 639).
Dräger recommends checking the charge of the power supply at least every
three weeks if the instrument is not stored in the charger module.
Disposal
This product must not be disposed of as municipal waste. This is
indicated by the adjacent icon.
You can return this product to Dräger free of charge. For information
please contact the national sales organisations and Dräger.
1)
Batteries and rechargeable batteries must not be disposed of as
municipal waste. This is indicated by the adjacent icon. Collect and
dispose of batteries and rechargeable batteries at battery collection
centres, in accordance with applicable regulations.
,