Télécharger Imprimer la page

MSW -DRAIN CLEAN 7.5 Manuel D'utilisation page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
EN
c)
If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
d)
Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
e)
In case of fire, use a powder or carbon dioxide
(CO
) fire extinguisher (one intended for use on live
2
electrical devices) to put it out.
f)
Children or unauthorised persons are forbidden to
enter a work station. (A distraction may result in loss
of control over the device).
g)
Regularly inspect the condition of the safety labels. If
the labels are illegible, they must be replaced.
h)
Please keep this manual available for future reference.
If this device is passed on to a third party, the manual
must be passed on with it.
i)
Keep packaging elements and small assembly parts in
a place not available to children.
j)
Keep the device away from children and animals.
k)
If this device is used together with another equipment,
the remaining instructions for use shall also be
followed.
REMEMBER! When using the device, protect
children and other bystanders.
2.3. PERSONAL SAFETY
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which can
significantly impair the ability to operate the device.
b)
The machine may be operated by physically fit
persons who are able to handle the machine, are
properly trained, who have reviewed this operating
manual and have received training in occupational
health and safety.
c)
The machine is not designed to be handled by persons
(including children) with limited mental and sensory
functions or persons lacking relevant experience and/
or knowledge unless they are supervised by a person
responsible for their safety or they have received
instruction on how to operate the machine.
d)
When working with the device, use common sense
and stay alert. Temporary loss of concentration while
using the device may lead to serious injuries.
e)
Use personal protective equipment as required
for working with the device, specified in section 1
(Legend). The use of correct and approved personal
protective equipment reduces the risk of injury.
f)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
g)
Do not overestimate your abilities. When using the
device, keep your balance and remain stable at all
times. This will ensure better control over the device
in unexpected situations.
h)
Do not wear loose clothing or jewellery. Keep hair,
clothes and gloves away from moving parts. Loose
clothing, jewellery or long hair may get caught in
moving parts.
i)
Remove all adjusting tools or spanners before turning
the device on. A tool or spanner left in the revolving
part of the device may cause injury.
j)
Use eye, ear and respiratory protection.
k)
The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
10
2.4. SAFE DEVICE USE
a)
Do not overload the device. Use the appropriate tools
for the given task. A correctly-selected device will
perform the task for which it was designed better and
in a safer manner.
b)
Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
off). Devices which cannot be switched on and off
using the ON/OFF switch are hazardous, should not
be operated and must be repaired.
c)
Make sure the plug is disconnected from the socket
before
attempting
any
adjustments,
accessory
replacements or before putting the device aside.
Such precautions will reduce the risk of accidentally
activating the device.
d)
When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
e)
Keep the device in perfect technical condition. Before
each use check for general damage and especially
check for cracked parts or elements and for any other
conditions which may impact the safe operation of the
device. If damage is discovered, hand over the device
for repair before use.
f)
Keep the device out of the reach of children.
g)
Device repair or maintenance should be carried out by
qualified persons, only using original spare parts. This
will ensure safe use.
h)
To ensure the operational integrity of the device, do
not remove factory-fitted guards and do not loosen
any screws.
i)
When transporting and handling the device between
the warehouse and the destination, observe the
occupational health and safety principles for manual
transport operations which apply in the country where
the device will be used.
j)
Avoid situations where the device stops working
during use due to excessive loading. This may result in
overheating of the drive elements and damage to the
device.
k)
Do not touch articulated parts or accessories unless
the device has been disconnected from the power
source.
l)
At locations where there is a high risk of mechanical
damage, use a reinforced hose for compressed air
connections.
m)
Before each use ensure the nozzle is correctly installed
in the device and that the hose is correctly attached
and undamaged.
n)
Do not cover the air intake and outlet.
o)
The device is not a toy. Cleaning and maintenance may
not be carried out by children without supervision by
an adult person.
p)
It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
q)
Keep the device away from sources of fire and heat.
r)
Do not overload the device.
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there
is still a slight risk of accident or injury when using
the device. Stay alert and use common sense when
using the device.
10
Rev. 21.02.2022
3. USE GUIDELINES
The device is intended for clearing pipes.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
4
1
2
7
5
3
6
1.
Spiral
2.
Locking ring (locks / unlocks the spiral feed)
3.
Aditional handle (its position indicates the spiral feed
direction (F - forward; R - backward; 0 - feed stop)
4.
Waterproof plug
5.
Spiral drum
6.
Reversing switch (L - left rotation; R - right rotation)
7.
On / Off switch (The harder this button is pressed, the
higher the rotational speed)
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Keep the device away from any hot surfaces Position the
device such that you always have access to the power
plug. The power cord connected to the appliance must be
properly grounded and correspond to the technical details
on the product label. Place the device as close to the pipe
inlet as possible. Only use special reinforced gloves to
hold the cable - do not use any soft gloves! Check that the
waterproof drum plug (4) is fitted and check the cable for
damage - replace it if worn, corroded or bent.
3.3. DEVICE USE
3.3.1 RING JAWS
Turn the locking ring (2) counterclockwise so that the jaw
grasps the cable and creates a large force to facilitate
removal of the blocking material and to prevent the cable
from entering the drum. Turn the locking ring (2) clockwise
to loosen the cable and make it easier to slide and retract
into the drum.
WARNING! If the cable protrudes from the device less than
20 cm or more than 600 cm, do not set the ring in the locked
position as this may damage the jaw and the cable and
threaten the user's safety.
3.3.2 ON / OFF SWITCH - SPEED CONTROL
The device is turned on / off with switch (7) acting as
a throttle - the harder it is pressed, the higher the device's
speed.
Rev. 21.02.2022
EN
3.3.3 SELECTING THE ROTATION DIRECTION
To select the cable rotation direction, set the switch (6) in
the L - forward or R - reverse position. The reverse (return)
direction must only be used to unlock the stuck cable.
R
L
3.3.4 CABLE FEED
Press the rotation direction button L forward and backward.
To move the cable forward, press the on / off switch (7)
lightly and move the handle (3) towards position F.
To retract the cable towards the device, press the on / off
button (7) lightly and set the handle to position R.
When the feed button R is pressed, the cable moves in the
opposite direction. When the handle is in the "O" (neutral)
position, the cable feed is stopped regardless of the rotation
direction.
3.3.5 UNCLOGGING PIPES
For safety reasons, keep the device within 150 mm of the
pipe inlet. Also, do not hold it right next to the pipe inlet as
it will make it difficult to observe the cable behavior during
operation.
11
11

Publicité

loading