Troubleshooting

If the equipment is not working properly, consult the
following table of possible causes and recommended
remedies before contacting Customer Service.
PROBLEM
The suction motor does not start when the on button is
pressed.
The suction motor starts, but the lights do not switch on
when the lights button is pressed.
The motor starts but cooking fumes are not extracted.
The suction motor stops suddenly after running for a
few minutes.
When the motor is off the timed switch-off button is lit
with a red light.
If the cause of the problem cannot be found,
switch off the equipment, remove the plug and
contact Customer Service.
POSSIBLE CAUSES AND RECOMMENDED REMEDY
The plug is not connected to the socket or there is a
mains failure.
The electrical connector on the suction motor is
disconnected.
Bulbs blown. Replace them.
Bulbs not fully inserted.
Transformer faulty. Contact Customer Service.
Metallic or active charcoal filters clogged. Clean metallic
filters or replace the active charcoal filters. Disconnect
the hood from the mains before accessing internal parts.
Duct clogged.
This is normal if the timed switch-off has been activated.
This is normal after 30 hours of operation. The warning
light (steady red light) signals the need to clean the
metallic filters. To eliminate the filter saturation warning
light, simply hold the button down for a few seconds.