INSTALLATION
POSITIONING
• The radiator must be positioned horizontally in order for
a correct function.
• The radiator must be positioned according to the
applicable standards and the minimum distances as
specified in picture 1.
• If installed in a bathroom, picture2, the radiator must
be positioned "outside" zone 2 or in zone 2 insofar as no
operating controls (buttons, switch, etc...) are in reach of
person in the bath or under the shower.
• The radiator must be fixed to the wall using the wall
brackets supplied with the radiator and shall not be
located underneath an electrical socket.
FIXING
• Mark out the position of the bracket screw holes as
shown in the pictures 3-5 (500H) and 6-8 (250H).
NOTE: Wall screws are not included in the installation
packs. Installer is responsible for using suitable wall screws.
• For the lengths of 900-1800 mm grill supports are
needed, picture 9. Install the upper parts 1 of the grill
supports, picture 10, symmetrically and with around
same span on the convection plate, picture 11. Open the
flip hooks more if needed.
• Lift the radiator on wall brackets and mark vertical
distances of the grill support centers on the wall.
Remove the radiator and mark the wall bracket top level
horizontally to the points. Wall brackets 2 of the grill
supports shall be mounted on these positions. - Screws
43 mm from the bracket top level, picture 12. Number
of the grill supports shown in picture 13.
NOTE: Special mounting rail available for pasterboard walls.
At least one screw into a solid beam, picture 14.
• For walls made of materials for example hollow bricks or
plasterboard, please consult a specialized fixing supplier.
2 |
M16MI414_A05_01_18_MILO ROCK HORIZONTAL.indd 2
IMPORTANT: In all cases it is strongly recommended
that a suitably qualified professional installer or similar
tradesperson carries out the installation. The installer is
responsible for the installation result and reliability.
MOUNTING
• Lift the radiator on the wall brackets. Use the self-
cutting screws supplied with the radiator. – There is no
pre-drilled hole in the convector plate on the radiator
IMPORTANT: Screw position at the lower part of the long
hole in the bracket, pictures 18 and 22.
• Install the top grill on its place, make the wall distance
adaptation and straightening 1 with help of grill
supports and fasten the HEX screws with Allen key 2
through the top grill opening.
IMPORTANT: Thermostat must never rest on the
ground. The thermostat must be set up away from
water ejections, direct sunlight or any direct thermal
disturbance such as a lamp, television, heating pipe, etc.
ELECTRONIC CONNECTION
• The electrical installation must comply with local/
national regulations.
• The radiator must be connected to the electrical supply
using the supply cable fitted to the unit.
• If the radiator is installed in a bathroom or shower
room, it must be protected with a residual current
device (RC D) with a rated residual current not
exceeding 30 mA.
IMPORTANT: The radiator should be connected by a
suitable and qualified electrician. Please refer to the
wiring diagrams in pictures 25 and 26.
WARNING 1: The natural stone material of the appliance
shape may slightly evolve due to a repeated use overtime
at a high temperature.
WARNING 2:The heater must not be used if the panel is
damaged