SYSTEM FAULTS
GB
PROBLEMS WITH MANUAL RESET
These problems are reset by the user: by pressing key
it back on. If the fault is present keys
Up alarm
This fault is displayed if the length of the chain is less than the value set on
the FUNCTIONS\UP ALARM menu.
The window shown below appears when this problem is present:
No laps sensor
This fault is displayed if the laps sensor does not detect the gypsy move-
ment within four seconds (for a longer time if auto free fall management is
p
activated) when key
switches are pressed.
Check the distance between the magnet and sensor, operation of the laps
sensor and the wiring/connections.
The window shown below appears when this problem is present:
Sensor failure
This fault is displayed if the chain counter detects a short circuit in the
sensor for more than four seconds (for a longer time if auto free fall mana-
gement is activated) when key
or other switches are pressed.
Check operation of the laps sensor and the wiring/connections.
The window shown below appears when this problem is present:
CONFIRMATION MESSAGES
Confirmation messages that may appear on the state line are shown below.
Stop
When no commands are sent to the windlass, the following window is di-
splayed:
Memory stored
As soon as four seconds elapsed from the last operation was completed
(up, down, automatic down, free fall), the chain counter stores the length of
the lowered chain in the EEPROM memory.
The window shown below is displayed while the data are being saved:
Locked Controls
Once the time set in the LOCKED KEYS parameter has elapsed, the instru-
ment will inhibit the functionality of the
pressing these keys will have no effect. Pressing the
reactivate the functionality of the
32
, q
(UP, DOWN) are disabled.
p
or q (UP or DOWN ) of the chain counter or other
or q (UP or DOWN ) of the chain counter
p
and q and (UP and DOWN) keys;
p
and q (UP and DOWN) keys.
p
=
(SELECT) or turn off the chain counter and turn
=
key (SELECT) will
UP ALARM
SPEED
0 M / M
NO SENSOR
SPEED
0 M / M
SENSOR FAILUR
SPEED
0 M / M
STOP
SPEED
0 M / M
MEMORY STORED
SPEED
0 M / M
LOCKED
SPEED
0 M / M
CHC1102M GB F - REV005B