SP EC I FI C AT IO N S
Installation Requirements
The speed oven can be installed in a standard or flush inset
application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
If the speed oven is installed above or below a Wolf E series
oven in a flush inset application, a 6 mm reveal is required.
IN S TA LL AT I O N R E Q U IR E M E NT S
BA SE S UP P O RT
610 mm Model
762 mm Model
TRI M OV ERLA P
610 mm MO D EL
7 62 mm M OD E L
Top
5 mm
Bottom
0 mm
Sides
18 mm
Electrical Requirements
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustrations
on the following page. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation.
E LE C TR I CAL REQUI R EM ENT S
Electrical Supply
Service
Power Cord
M I N
57 kg
57 kg
5 mm
0 mm
98 mm
RATING PLATE
Rating plate location
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
220240 V AC, 50 Hz
2800 W
1.2 m
wolfappliance.com | 3