CONNECTING MONOPHASE
APPLIANCES
The connection is to be realised with
three conductors of 2.5 mm
one is green/yellow for the earth.
The connection to the mains is to be done
via terminals A and B of the thermostat
(see fig. 2).
The green/yellow conductor will be
connected to terminal
- The protection class of the appliance is: I.
!
The covers closing the electric group provide protection against the involuntary
touching of the active electric parts under voltage.
- The connection to the mains is to be realised in accordance with the installation
diagram found in this installation manual and on the plate at the bottom of the
appliance, by paying attention to the connection to the correct phases.
!
It is FORBIDDEN AND DANGEROUS to start-up the appliance without the
professional installation by a specialist provided with protection against the
electric contacts.
For the good functioning of the appliance, we recommend the usage of a
protection relay in the mains of your building
Maintenance: Attention! Before doing any maintenance or repair interventions,
disconnect the appliance from the electric supply. The maintenance and repair
works have to be carried out by qualified personnel.
During the repair and maintenance works, the appliance has to restored into its
original condition.
The repair works have to be documented by your technician in order that guaranty
should be preserved.
ENG
!
CONNECTING TRIPHASE APPLIANCES
The connection is to be realised with four conductors of
2
, of which
2.5 mm
The connection to the mains is to be done via terminals
B1, B2 and B3 of the thermostat (see fig. 3, 4 and 5).
The green/yellow conductor will be connected to
terminal
For a 400 V tri supply without neutral, modify the
internal connections
diagram in fig. 3.
Regarding a 230 V tri connection, please, follow the
diagram in fig. 4.
Such connections have to be done by an approved
2
, of which one is green/yellow for the earth.
by following the connection