ENGLISH
1. DESCRIPTION
The DRIFT display cases are available in four different lengths, also for the completion of back-to-back lines. The
case is appropriate for preservation and self-service sale of fresh pre-packed products. Its main features and dimen-
sions are clearly illustrated in drawings 1, 2, 3. As for its weights, crating included and excluded, see table I. A wide
variety of optional accessories is also available for enhanced functions. To this respect, contact the authorised
after-sales service only.
2. TRANSPORTATION
The display case is contained in a specially crated package that enables transportation by the use of fork lifts. Handle
the machine on its own pallet or on a similar platform; use a fork lift, either manual or electric, provided it is adequate
for handling such appliances and it has the requisite lifting capacity (fig. 4 and table I). Handling is reserved for
the authorised after-sales service.
3. DELIVERY AND STORAGE
Prior to accepting the case from the carrier, check the conditions of the package. If it is showing visible damage, the
machine may have suffered some consequences. If so, unpack the machine in the presence of the carrier and sign,
under protest, the delivery bill. The manufacturer assumes no liability for any damage caused by transportation or
wrong handling during storage. Unpacking is reserved for the authorised after-sales service. Storing tempera-
ture must be between -25°C and +55°C, air humidity between 30% and 95%. Keep the case safe from direct sunlight
and from the elements.
4. INSTALLATION AND AMBIENT CONDITIONS
The display case must not be installed in premises containing explosive gas substances. It can
neither be used in the open nor exposed to the rain.
Before connecting the case make sure that its rating plate data correspond to the features of the existing elec-
trical installation (fig. 8 and tab. III). For correct operation, the machine must be placed on a level floor (fig 5),
far from sources of heat and/or direct sunlight, d o or s, wi nd o ws , f a n s o r ven til a tio n o u tle ts (see page
4 - fig.6). It must also be granted a reasonable free front area for customer service.
IMPRTANT: The cabinet needs a minimum front clearance of 1,5 mt, which is required to allow
use by customers, enable servicing by the personnel and also ensure the air flow required for
condenser cooling. The minimum distance between the back of the cabinet and the wall is 10
cm.
The display case must be housed in a room conforming to the ambient requirements mentioned
in fig. 7 and tab. II.
IMPORTANT: placing fixed panels on the top of the cabinet is advised against, as this part must
be accessible for servicing purposes.
5. ELECTRICAL CONNECTION
IMPORTANT: INSERT IN THE FIXED WIRING A MEAN FOR DISCONNECTION FROM THE SUPPLY MAINS
HAVING A CONTACT SEPARATION IN ALL POLES THAT PROVIDE FULL DISCONNECTION UNDER OVER-
VOLTAGE CATEGORY III CONDITIONS IN ACCORDANCE WITH THE WIRING RULES (see fig. 17). The
position of the cut-out switch must enable its actuation in any EMERGENCY situation (maximum
distance 3 m). Show the position of the cut-out switch to any prospective operator.