Technical Data - Lenze EPL-10200-EI Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
General data / Application conditions
Conformity
Approvals
DC supply voltage
DC supply voltage
Supply conditions
Climatic conditions
Temperature range
Temperature range
Power derating
Vibration resistance
Permissible mounting positions
Free space
Enclosure
Total insulation
L
CE
Low-Voltage Directive (73/23/EEC)
UL 508C
Underwriter Laboratories (File-No. E132659)
Power Conversion Equipment
Voltage
+18 VDC - 0 % ... +30 VDC + 0 %
Current
max. 4.2 A at 24 VDC:
Note: The outputs of the extension boards must be
supplied externally
The device must not be connected to voltages > 50 V against PE.
The device must not be used in mains circuits.
Class 3K3 to EN 50178
(without condensation, average relative humidity 85 %)
Transport
-25 °C ... +70 °C
storage
-25 °C ... +60 °C
Operation
0 °C ... +40 °C without power derating
+40 °C ... +55 °C with derating
of output currents at t
> +40 °C: 2.5 %/K
a
Resistant to acceleration up to 0.7 g
vertical
≥ 100 mm below and above
IP 20
The degree of insulation of the device depends on the degree of insulation of
the voltage source and the components connected.
EDK10200EV3 DE/EN/FR 5.0

Technical data

200 mA at +24 V (Drive PLC supply)
max. 1A per output at Drive PLC