6. Faults

6. Faults
Faults
Status display shows red warning
dot on the dial
EN
The pointer position is
arbitrary and does not
correspond to the process
pressure.
Medium can ingress into the
reference chamber.
Despite a damaged
diaphragm element, due to the
second barrier no exchange
has occurred between
process and ambience
Following any failure or shut-down of the plant all instruments should
be checked and, if necessary, replaced before recommissioning the
plant.
16
WIKA operating instructions disphragm pressure gauge, model PG43SA-D
Causes
Measuring
Replace
instrument is
measuring
defective and
instrument. The
dismounting of
can no longer
be used as a
the measuring
reference for
instrument is
the process
described in
pressure.
chapter 8.
Measures