Preparing For Commissioning And Installation; Start-Up - ATIKA ADH 204 Notice Originale

Dégauchisseuse / raboteuse
Masquer les pouces Voir aussi pour ADH 204:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Electrical safety
Extension cable to be designed in compliance with IEC 60
245 (H 07 RN-F) having a core cross-section of at least:
− 1.5 mm² for cable lengths up to 25 m
− 2.5 mm² for cable lengths over 25m
Long and thin connection lines result in a potential drop. The
motor does not reach any longer its maximal power; the
function of the device is reduced.
Plugs and coupler outlets on connection cables must be
made of rubber, non-rigid PVC or oth er thermoplastic
material of same mechanical stability or be covered with this
material.
Protect yourself against an electric shock. Avoid touching
earthed parts with your body.
The connector of the connection cable must be splash-
proof.
Wind off completely the cable when using a cable drum.
Do not use the cable for purposes for which it is not me ant.
Protect the cable against heat, oil and sharp edges. Do
not use the cable to pull the plug from the socket.
Regularly check the saw cable and if dama ged, have it
renewed by a recognised skilled electrician.
When running the connection line observe that it d oes not
interfere, is no t squeezed, bended and the plug connection
does not get wet.
Regularly check the extension cables and replace them if
they are damaged.
Do not use any defective connection cables.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current
circuit breaker (30 mA).
The electrical connection or repairs to electrical parts of
the machine must be carried out by a certified electrician
or one of our customer service points. Local regulations –
especially regarding protective measures – must
observed.
Repairs to other parts of the machine must be carried out
by the manufacturer or one of his customer service points.
Use only original spare parts a nd accessorie parts.
Accidents can arise for the user through the use of other
spare parts. The m anufacturer is not liable for any
damage or injury resulting from such action.
Preparing for commissioning
To achieve flawless fun ctioning of the machine, please
follow the instructions listed:
Place the surface planing and thicknessing machine at a
location which meets following conditions:
− secured against slipping
− free of vibrations
− even
− free of tripping hazards
− adequate light
Before each use, check
− connection cables for defects (cracks, cuts, etc.)
Do not use any defective cables.
− Are the pushing blocks or bars handy?
− Is the u nused blade shaft covered by th e blade shaft
guard?
When working do not stand directly in front or behind the
machine but stand to the side.
You have to attach the following parts:
Rubber feet (7)
Guide plate (1)
Attach the guide plate (1) to the ta ble location provided for
this.
Secure the guide plate using two w ashers A 6.4 a nd two
screws M6x25.
Blade shaft guard (14)
Attach the complete blade shaft guard (14) to the table
location provided for this.
Secure the blade shaft guard using the star grip screw (11).
Securing on the workbench
Drill four holes into y our workbench as shown in the picture.
Secure the surface planing and thicknessing machine onto the
workbench using 4 screws (M8). You can also secure the
surface planing and thicknessing machine onto a work plate. In
this case the plate must be safely secured onto the workbench.

Start-up

Mains connection
be
Compare the voltage listed on the machine's type plate, e.g.
230 V, with the mains voltage and connect the machine to a
suited and and properly earthed electrical socket.
Alternating
Use a shockproof plug, mains voltage 230 V with residual
current circuit breaker and 10 A inert fuses.
Use connection cable or extension cable respectively with a
cross section of at least 1,5 mm².
On / Off Switch
Do not use any device where the switch can not be
switched on and off. Damaged switches must be repaired or
replaced immediately by the customer service.
Switch on
Fold up the yellow hinged cover.
If the hinged cover is locked into place, you have to
push the red knob in arrow direction at first.
19
A
B
C
D
current
E
motor:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

004000020000

Table des Matières