TECHNICAL DATA
Volts .....................................................................
........230 V ............... 230 V ...........230/240 V ................110 V ............... 240 V
Mains frequency ..................................................
..........50 Hz ............... 50 Hz ..................50 Hz ................50 Hz ............... 50 Hz
Fuse.....................................................................
..........16 A ................. 10 A.....................13 A...................25 A .................. 10 A
Safety class ........................................................
.............I ....................... I ..........................I ........................I ....................... I
Type of protection
.....IP X4 ................IP X4 .................. IP X4 ................IP X4 ............... IP X4
Total connected load............................................
AS 300 ELCP ...................................................
......3600 W ............ 2300 W ...............3000 W .............2750 W ............ 2400 W
AS 500 ELCP ...................................................
......3600 W ............ 2300 W ...............3000 W .............2750 W ............ 2400 W
AS 300 ELAC ...................................................
......3600 W ............ 2300 W ...............3000 W .............2750 W ............ 2400 W
Power
...............................................................
......1200 W ............ 1200 W ...............1200 W .............1000 W ............ 1200 W
IEC
Rate of air flow
AS 300 ELCP ...................................................
........222 m
AS 500 ELCP ...................................................
........222 m
AS 300 ELAC ...................................................
........228 m
Vacuum ................................................................
........250 mbar ......... 250 mbar.............250 mbar...........230 mbar .......... 250 mbar
Tank volume
AS 300 ELCP ...................................................
..........30 l ................... 30 l ......................30 l ....................30 l ................... 30 l
AS 500 ELCP ...................................................
..........50 l ................... 50 l ......................50 l ....................50 l ................... 50 l
AS 300 ELAC ...................................................
..........30 l ................... 30 l ......................30 l ....................30 l ................... 30 l
Maximum power off-take .....................................
......2400 W .............1100 W ...............1800 W .............1750 W ............ 1200 W
Suction hose diameter .........................................
...... ø 36 mm........... ø 36 mm ..............ø 36 mm ........... ø 36 mm ...........ø 36 mm
Weight according EPTA-Procedure 01/2003
AS 300 ELCP ...................................................
..........10 kg ................ 10 kg ...................10 kg .................10 kg ................ 10 kg
AS 500 ELCP ...................................................
..........11 kg .................11 kg ................... 11 kg .................11 kg ................ 11 kg
AS 300 ELAC ...................................................
..........12 kg ................ 12 kg ...................12 kg .................12 kg ................ 12 kg
Power supply cord ...............................................
... H05RR-F3G1,5 ... H05RR-F3G1,0 ..... H05RR-F3G1,5 ... H07BQ-F3G2,5 .. H05RR-F3G1,5
Typically the A-weighted sound pressure level of the tool is
less than 70 dB (A). The noise level when working can
exceed 85 dB (A).
The noise level when working can exceed 85 dB (A).
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Appliances used at many different locations including open air
should be connected via a residual current device (FI, RCD,
PRCD) of 30mA or less.
Before doing any work on the machine, pull the plug out of the
socket.
Make sure the machine is switched off before plugging in.
Never suck up into the machine any inflammable or explosive
solvents, or liquids like petrol, oil, alcohol, thinners, or small
particles (such as metal filings or ash) that may be hotter than
60°C - otherwise there is danger of explosion or fire!
You are not allowed to use the appliance in the vicinity of
inflammable gases or substances.
Do not put appliances or accessories into operation, if: the
appliance has recognizable damage (cracks/breaks), the
mains connection lead is defective or shows signs of cracking
or aging, there is a suspected non-visible defect (after having
been dropped).
Do not point the nozzle, hose or tube at people or animals.
The plug socket on the appliance may be used only for the
purposes defined in the usage instructions.
If any foam or water egresses, switch off immediately. Empty
the container and, if need be, the pleated filter.
Acids, acetone and solvents can corrode the appliance
components.
In the event of misuse, improper operation or unprofessional
repair work no liability shall be assumed by us for any damage
incurred.
Do not use suction on health damaging dusts.
Not suitable for sweeping up liquids which form a large foam.
24
ENGLISH
EU
CH
GB 230/240 V
GB 110 V
/h .......... 222 m
/h ..............222 m
/h ............192 m
3
3
3
/h .......... 222 m
/h ..............222 m
/h ............192 m
3
3
3
/h .......... 228 m
/h ..............228 m
/h ............192 m
3
3
3
If the mains connection cable is damaged the machine must
not be used.
Have the faulty mains connecting lead replaced by your
Milwaukee service representative or a qualified electrician prior
to using the appliance again.
Make sure that the mains connection cable is not damaged,
squashed, bent, or damaged by being run over or in any other
way.
Extension cables to the mains must at least be protected from
water spray and contain an earth lead.
This appliance is not intended for use by persons (including
children) with limited physical, sensory or mental capabilities or
insufficient experience and/or knowledge unless they are
supervised by a person who is responsible for their safety or
have been instructed by them in the safe use of the appliance.
Children should be supervised in order to ensure that they do
not play with the tool.
Before liquids are picked up, always remove the filter bag.
Insert filter for wet operation. Check that the float works and
level indicator hose properly. If foam develops or liquid
emerges, stop work immediately and empty the dirt tank.
CAUTION! Clean the water level demarcation and inspect it for
damage regularly.
The machine is to be connected to the mains via an
10A / 13A / 16A (230V), 25A (110V) contact-breaker or a fuse.
CAUTION! This device must not be used or stored outdoors in
wet conditions.
The power supply cord may only be replaced with the type
described in the operation manual.
Measures must be taken to ensure that there is adequate
ventilation in rooms in which the device is used as a dust
extractor. Any national regulations in this regard must be
complied with.
CAUTION! The device may contain noxious dust. Emptying
and maintenance procedures, including the removal of dust
collectors, may only be carried out by trained personnel
wearing appropriate protective gear. Do not operate without
complete filtration system.
AU/NZ
Before using the device, users must be given information on
the use of the device and on how to handle and dispose of the
hazardous substances for which the device is intended to be
used.
Picking up environmentally hazardous materials.
Materials picked up can present a hazard to the environment.
Dispose of the dirt in accordance with legal regulations."
SPECIFIED CONDITIONS OF USE
The appliance is suitable for picking up dry, non-flammable
dust and liquids.
/h ........... 222 m
/h
3
3
/h ........... 222 m
/h
3
3
/h ........... 228 m
/h
3
3
The vacuum cleaners described in this operating manual are
suitable for
for separation of dust with an exposure limit of greater than 1
mg/m³, (dust class L).
commercial use, e.g. in hotels, schools, hospitals, factories,
shops, offices and rental businesses.
Any other use is considered as improper use. The
manufacturer accepts no liability for any damage resulting from
such use. The risk for such use is borne solely by the user.
Proper use also includes proper operation, servicing and
repairs as specified by the manufacturer.
CONNECTING ELECTRICAL APPLIANCES
Use the socket on the vacuum cleaner for the purpose defined
in the operating instructions only.
Before plugging an appliance into the appliance socket:
Switch off the vacuum cleaner. Switch off the appliance to be
connected.
CAUTION! Follow the operating instructions and safety
instructions for appliances connected to the power tool socket."
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in
conformity with the following standards or standardized
documents. EN 62233, EN 60335, EN 55014-1, EN 55014-2,
EN 61000-3-2, EN 61000-3-3, in accordance with the
regulations 2006/42/EC, 2004/108/EC, 2011/65/EU (RoHs)
Winnenden, 2010-11-30
Rainer Kumpf
Manager Product Development
Authorized to compile the technical file
MAINS CONNECTION
Connect only to single-phase AC current and only to the
system voltage indicated on the rating plate. It is also possible
to connect to sockets without an earthing contact as the design
conforms to safety class II.
MAINTENANCE
The device must be sent to a Milwaukee customer service
centre at least once a year for a technical inspection.
During maintenance and cleaning, handle the vacuum cleaner
in such a manner that there is no danger for maintenance staff
or other persons.
In the maintenance area:
- use filtered compulsory ventilation
- wear protective clothing
- clean the maintenance are so that no harmful substances get
into the surroundings
Tests and approvals:
Electrical tests must be performed in accordance with the
provisions of safety regulations (BGV A3) and to DIN VDE
0701 Part 1 and Part 3. In accordance with DIN VDE 0702
these tests must be performed at regular intervals and after
repairs or modifications."
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or
directly at: Milwaukee Electric Tool, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
ACCESSORIES
Filter Element - round
AS300/500ELCP
4932 3523 04
Filter Element - flat
AS300ELAC
4932 3523 05
Fleece filter bag 30l
AS300ELCP
4932 3523 07
Fleece filter bag 50l
AS500ELCP
4932 3523 08
Disposal bag 30l
AS300ELCP+ELAC
4932 3523 09
Disposal bag 50l
AS500ELCP
4932 3523 10
SYMBOLS
Please read the instructions carefully before
starting the machine.
CAUTION!
Always disconnect the plug from the socket
before carrying out any work on the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to
an environmentally compatible recycling facility.
ENGLISH
25

Publicité

loading

Ce manuel est également adapté pour:

As 500 elcpAs 300 elac