7. Information for the specialist electrician

H
Caution: Important installation instructions.
Please follow all instructions since
incorrect installation can lead to
the destruction of the motor and the
switching unit.
• A locking switch is here necessary (no simultaneous
UP and DOWN commands).
• The operations with the service clamps may be
accomplished only by an electrical specialist.
• Motors with electronic limit stops can be connected in
parallel.
• In this case the maximum load of the switching unit
must not be exceeded.
• When changing the running direction the switchover
must be effected through an off-position.
• When changing the running direction the switchover
time must be at least 0.2 s.
• With a three-phase network, please use the same
external conductor in order to control the UP and
DOWN directions.
• Connecting cables with plug connectors of the
Hirschmann Company are tested and approved with
couplings of the Hirschmann Company.
• In order to prevent a malfunction caused by coupling,
the supply line (ref. NYM) from the actuator/switch to
the motor must not exceed 100m in case of motors with
electronic end stops.
H
Attention: the connection diagram of the 4 or 5 pole-connector is
different. A 4-pole connecting cable must be used for the motors.
The GEIGER Flat4 with light blue ring. The motor might start running
unexpectedly if a 5-pole connecting cable with continuous power
supply is used.

8. Setting of the end stops

General information
In order to set the end positions of the GJ56.. E11 motors, any setting switch can be used that
has a programming key or that allows a simultaneous UP/DOWN command. In this case, the
UP/DOWN keys must be activated simultaneously instead of the programming key.
Article number / GEIGER setting switch
M56F152
M56F153
M56F154
I
Important: please observe the connecting diagram on the back of the
GEIGER setting switch.
Factory setting
• The motor is set on the middle position at the factory.
• The motor command is in normal operation.
www.geiger.de
with service terminal (D), 5 wires, SMI compatible
with service terminal (CH), 5 wires, SMI compatible
with service terminal (D), 4 wires
Mains: 230V / 50Hz
L1
N
PE
PE
N
1
2
3
Electronic /
mechanical
limit stop
EN
5
EN