Language; Set Point - Zodiac O'Clair pH First Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Adjustments: " Program" menu
A
B
C
D
4.1.

Language

The default language displayed on the pH First is French.
You can choose between 6 languages for the LCD display: French, English,
German, Spanish, Italian and Dutch.
To change language when in the " Program" menu, enable the option list by
pressing the "CAL/ Enter " button (a small arrow appears on the right of the
screen and the language message flashes). Then select the language using the
"up" and " down" navigation buttons.
Accept the choice by pressing the "CAL / Enter " button.
4.2.
" Pr ogra m" menu - Default parameters
!
The pH First is factory preset with the following settings
(suitable for most cases):
a. Language: French
b. Set point: pH = 7.4
c. Dosage = acid
(injection when the pH is higher than the set point)
d. "OFA " over- feed protection: 240 minutes
e. Calibration = enabled in 2 points (pH7 & pH4)
f. Detection that filtration is in progress: enabled
However, there is an easily accessible "settings" menu for changing the settings
of your appliance to match them as closely as possible to your pool's require-
ments.
• To access the " Program" menu, the appliance must be ON. Simultaneously
press the " CAL / Enter " and "SET / Esc " buttons for about 5 seconds until the
LCD screen displays " Settings ".
This " Program" menu gives access to the following adjustments:
– Language

– Set point

– Type of dosage
– Time of using the " OFA" over- feed protection
– Type of calibration
– Detection that filtration is in progress
• To exit the "Program" menu, press the "SET / Esc " button and select " Yes "
or "No ", using the " up " and " down " navigation buttons to save the
new settings or not. Accept the choice by pressing the "CAL / Enter" button.
Figure
C.
4.3.
Set point
The default set point on the pH First is 7.4 pH.
To change it when in the " Program" menu, enable the option list by pressing
the " CAL/ Enter " button (the pH value flashes). Then select the value chosen
using the " up" and " down " navigation buttons. The adjustment is made in
increments of 0.1 pH.
Accept the choice by pressing the "CAL / Enter " button.
Note:
: It is also possible to directly access the set point by holding down the
" SET / Esc " button (keep pressing while changing the setting).
Figure
Figure
B.
A.