2.3.

Installation diagram

Installation of the pH First on the filtration system
!
Important:
The distance between the sensor and the injection point must not be
less than 60 cm.
The injection point must be the last element on the return line before the
pool.
Keep the sensor cable away from other power cords in order to prevent electri-
cal interference.
The maximum pressure in the pipes must not exceed 150 kpa.
To increase the life span of the peristaltic pipe, the pressure should not
exceed 100 kpa.
!
Important:
If the pool has a chlorinator, a heating system or any other equipment,
they must be situated after the pH sensor but before the acid injec-
tion point.
60 cm mini
EN
25