POOL Autosalt Manuel Utilisateur page 48

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

✓ Switch off the device and unplug the probe of the device. Close gates of the by-pass and bring out
the probe of the chamber of measure.
✓ Unscrew at half tank of the probe.
✓ Open the bottle of gel and expel the air. Pour the gel without making of air
bubbles.
✓ Re-screw the tank and tight hardly up to the abutment. The surplus of gel
is evacuated by the elastic ring.
✓ Proceed to a new calibration of chlorine measure (see §4.7)
It is recommended to use only spart parts and/or replacement units from POOL TECHNOLOGIE.
7/ MAINTENANCE OPERATIONS
1
SELFDIAGNOSIS PROGRAM
In case of defect of production or in case of doubt about the smooth running of the device, launch the auto
diagnosis program:
CHLORINATION SALT
CHLORINATION SALT
◄►
◄►
At the end of the test (around 1 minute), the device shows its result :
Code
Pump timer
The self-diagnosis detected a problem of power inside the controller box.
problem
You have to contact a Professional so that he proceeds to the repair of the controller box.
The self-diagnosis detected a defect coming from the cell.
1/ Check visually that the cell is not scaled (see
Cell
2/ Check that connexions to the borders of the cell are not oxidized and well squeezed.
problem
3/ In most of cases, this code shows that your cell is totally used and cannot produce chlorine anymore. You
have to contact a professional to proceed to the replacing of the chlorination cell.
The self-diagnosis detected no problem coming from electronic box or from the cell.
Test OK
If you have a problem of chlorine production, check that the rate of salt is upper than 2,5 kg/m
pH be closer of 7-7,2, an then contact a professional for an analysis.
2
SECURITIES OF THE DEVICE
Security
SECURITY
LACK OF WATER
OK
CAREFUL
LACK OF WATER
OK
AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082 – FR/EN/ES/DE - Rev.03.16
OK
OK
Function
Chlorination OFF
pH Regulation OFF
Chlorination STOP
pH Regulation ON
CHLORINATION SALT TEST
CHLORINATION SALT TEST
◄►
◄►
OK
OK
Causes / Remedies
§
)
6.4
Detection of a lack of water in waterworks.
Make sure of the presence of water in piping (check the opening of
valves).
Salt rate in the pool lower than 2,5 Kg/m
1/ Look at the present salt rate in the pool.
2/ Add salt as to obtain 5 kg/m
3/ Make Salt probe calibration (see § 5.2).
Cause / Action
3
.
3
of salt.
3
and that the
22

Publicité

Table des Matières
loading

Produits Connexes pour POOL Autosalt

Ce manuel est également adapté pour:

PoolsquadPoolsquad amperoPoolsquad pro

Table des Matières