Accessories Holder; Salt / Temperature/ No Water Sensor; Grounding Electrode - POOL Autosalt Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3

ACCESSORIES HOLDER

1/ Install the accessories holder horizontally.
2/ Install it, after all other treating or heating equipment, but before the chlorination cell.
3/ Respect the water flow direction (the arrow shows the direction of water flow and must be visible on top
of the holder).
SALT / TEMPERATURE / NO WATER SENSOR (length = 2m)
4
1/ Screw and tighten by hand the salt/temperature sensor (Never with crowbar) on the top of the holder. No
Teflon is needed.
2/ Plug the sensor under the device on the DIN jack 6 pins

GROUNDING ELECTRODE

5
1/ Hand screw the grounding electrode into the accessories holder. No Teflon is needed.
2/ Connect the electrode to a ground rod (not supplied) complying with specifications of the installation
standards in force in your country on the day of installation. Under no circumstances, this precedent
affirmation doesn't be assimilated to safety grounding, the use of yellow or green thread is banished.
3/ Tighten the upper nut of the electrode while holding the lower nut with a flat spanner to avoid creating an
irreversible leak at the connection level.
For the Poolsquad® Model, in addition
AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082 – FR/EN/ES/DE - Rev.03.16
Flow sensor in option
6

Publicité

Table des Matières
loading

Produits Connexes pour POOL Autosalt

Ce manuel est également adapté pour:

PoolsquadPoolsquad amperoPoolsquad pro

Table des Matières