PH CORRECTIVE MODE (ACID OR BASIC)
The device is configured to regulate the acid mode (make the pH go down). If necessary, you could change in
basic mode (make the pH rise) by using the setting menu :
REGUL. PH
REGUL. PH
◄►
◄►
OK
OK
Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a pH
regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks and
damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other factors may
cause damage, in particular :
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable...)
- manual processing of supplements excessive or not adapted (choc processing...)
- the non-compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and slats,
telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer's responsibility was engaged for a malfunction of the control or regulation device, it would be
limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to check the levels of
chlorine and pH each week with your usual analysis kit.

6/ MAINTENANCE

REACTIVATION

1
The device has a program which helps you to starting up again your device at the beginning of the season
PARAMETERS
◄►
OK
2
A/ PH PROBE CALIBRATION
2
The pH probe is submitted to a reference curve which according to the use of the pool, moves in the time.
e
ct
For an optimal regulation, it is important to proceed to a calibration every starting up again of the pool or
ur
when changing the probe.
e
✓ Before proceeding to a calibration, provide you calibration solutions pH7 and 10.
d
✓ Stop the filtration. Remove accessories holder and stop up by the origin cap.
u
✓ Put back the filtration on and use the setting menu :
p
H
REGUL. PH
REGUL. PH
p
ar
◄►
◄►
OK
OK
di
o
pH CALIBRATION
d
IN ACTION...
e
1
AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082 – FR/EN/ES/DE - Rev.03.16
PH CORRECTIVE TYPE
PH CORRECTIVE TYPE
ACID/BASE
ACID/BASE
◄►
◄►
▼▲
▼▲
OK
OK
Your device is now ready.
STARTING UP AGAIN
OK
pH CALIBRATION
pH CALIBRATION
OK
OK
PUT THE PH PROBE IN THE
PH10 SOLUTION
WAIT 5mn AND THEN
OK
▼▲
PUT THE PH PROBE IN THE
PUT THE PH PROBE IN THE
PH7 SOLUTION
PH7 SOLUTION
WAIT 5mn AND THEN
WAIT 5mn AND THEN
▼▲
▼▲
pH CALIBRATION 10
IN ACTION...
OK
OK