Télécharger Imprimer la page

Monacor PA-2460CD Mode D'emploi page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
5.7 Playing the first title
of each CD in the magazine
Press the button RANDOM [RDM]* (14) twice.
However, when the random replay is activated
(indication RANDOM, also see chapter 5.6),
press the button only once. The display shows
RANDOM and DISC. The unit changes to a CD
selected at random and replays the first title.
Then it changes to another CD selected at ran-
dom and replays its first title, etc.
To stop this replay function, press the button
RANDOM or CLEAR (4). The function is also
deactivated when actuating the button REPEAT
[RPT]* (15) or INTRO [SCN]* (16).
5.8 Shortly playing the beginning
of each title of a CD
To shortly replay the beginning of each title of
the CD currently playing for 10 seconds only,
press the button INTRO [SCN]* (16). The display
shows INTRO (h). To stop the replay of the
beginning of each title, press the button
The function is also deactivated when actuating
the button RANDOM [RDM]* (14) or REPEAT
[RPT]* (15) and when selecting another title or
CD.
5.9 Compiling an individual
title sequence
For only playing selected titles in a certain order,
a sequence of 24 titles as a maximum may be
programmed from a CD.
5.9.1 Memorizing and
playing a title sequence
1) First set the unit to stop with the button
The display shows the number of titles and
the playing time of the last CD replayed.
2) Use the button
or
(7) to change to the
CD from which the title sequence is to be
compiled.
3) Press the button PROGRAM (3). The display
shows the indication PROGRAM, the number
of the CD selected and the first memory loca-
tion:
6
5
PROGRAM
4
3
2
1
Indication of the
programming mode
Note: The programming can be stopped at any time
with the button
(10).
4) Select the first title of the title sequence with
the button
(9). The display shows the title
number selected (e. g. "T03").
5) To confirm the title selection, press the button
PROGRAM. The next memory location "P-02"
is shown.
6) Repeat the steps 4 and 5 until all titles of the
title sequence are memorized. After 24 titles
have been memorized, the display shows
"P-25 T – –". Then no further title can be
selected.
7) To replay the title sequence, press the button
(8). The title sequence is repeatedly
replayed without interruption.
Note: While playing a programmed title sequence,
the buttons RANDOM [RDM]* (14), INTRO [SCN]*
(16) and
and
(7) have no function.
* Lettering on the remote control
5.9.2 Changing or
completing a title sequence
1) Set the unit to stop with the button
2) When pressing the button PROGRAM, the
memory locations (P- 01 ... P- 24) can be
selected successively. Press the button
PROGRAM repeatedly until the memory
location is shown on which another title is to
be memorized. Select the new title number
with the button
the button PROGRAM. Repeat the procedure
for further memory locations, if required.
3) If less than 24 titles have been programmed
up to this moment, the title sequence can be
completed with further titles. For this pur-
pose, press the button PROGRAM repeat-
edly until the next free memory location is
shown (e. g. "P- 19 T – –"). Select the next
desired title with the button
button PROGRAM to confirm. To complete
further titles, repeat the procedure.
4) To replay the title sequence changed, press
(8).
the button
.
5.9.3 Deleting the title sequence
Normal replay mode
To return from the replay of a title sequence to
the normal replay mode, the programmed title
sequence must be deleted.
1) Set the unit to stop with the button
2) Press the button CLEAR (4). The indication
PROGRAM disappears from the display.
3) With the button
started in normal order.
(10).
6 PC Control of the Unit via the
RS-232 Interface
The PA-2460CD can be controlled with a corre-
sponding terminal programme from a PC. Con-
nect the jack RS-232C IN (31) to the RS-232
interface of the computer. Adjust the following
parameters in the terminal programme:
Symbol rate: . . . . . . . . . 19 200 baud
Number of start bits: . . 1
Number of data bits: . . 8
Number of stop bits: . . . 1
Parity: . . . . . . . . . . . . . . none
The control commands of the possible functions
are listed in the following table in the hexadeci-
mal code:
Function
STX
Power on
02h
Power off
02h
Play
02h
Pause
02h
Stop
02h
Track
02h
Track
02h
Search
02h
Search
02h
Repeat
02h
Clear
02h
Random
02h
Folder
02h
Disc
02h
All rights reserved by MONACOR
manual may be reproduced in any form or by any means for any commercial use.
7 Maintenance of the Unit
Protect the unit against dust, vibrations, humid-
.
ity, and heat (admissible ambient temperature
range 0 – 40 °C). For cleaning only use a soft,
dry cloth, never use water or chemicals.
Note on sound interruptions and reading
errors
Cigarette smoke and dust easily penetrate
or
and confirm with
through all openings of the unit and settle on the
optics of the laser system. If this deposit should
cause reading errors and sound interruptions,
the unit must be cleaned by skilled personnel.
There is a charge on this cleaning, even during
the warranty time!
8 Specifications
and press the
Frequency range: . . . . . . . 20 – 20 000 Hz,
THD: . . . . . . . . . . . . . . . . . < 0.03 %
Channel separation: . . . . . > 70 dB
Dynamic range: . . . . . . . . . > 70 dB
S / N ratio: . . . . . . . . . . . . . . > 85 dB
Output level
analogue outputs: . . . . . 0.775 V
coaxial digital output: . . . 0.5 Vpp, S / PDIF
Power supply
.
mains voltage: . . . . . . . . 230 V~ / 50 Hz
emergency power supply: 24 V
the replay can now be
Ambient temperature: . . . . 0 – 40 °C
Dimensions (W × H × D): . 482 × 88 × 260 mm,
Weight: . . . . . . . . . . . . . . . 7.1 kg
Subject to technical modification.
Control command
ID
Cmd1-L
Cmd1-H
Cmd2-L
44h
31h
30h
44h
31h
38h
44h
32h
30h
44h
33h
30h
44h
34h
30h
44h
35h
30h
44h
36h
30h
44h
37h
30h
44h
38h
30h
44h
39h
30h
44h
41h
30h
44h
42h
30h
44h
43h
30h
44h
44h
30h
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction
±3 dB
power consumption: . . 20 VA max.
current consumption: . 1.5 A
2 rack spaces
Cmd2-H
BCC-L
BCC-H
30h
30h
31h
43h
30h
30h
39h
43h
30h
30h
32h
43h
30h
30h
33h
43h
30h
30h
34h
43h
30h
30h
35h
43h
30h
30h
36h
43h
30h
30h
37h
43h
30h
30h
38h
43h
30h
30h
39h
43h
30h
30h
31h
44h
30h
30h
32h
44h
30h
30h
33h
44h
30h
30h
34h
44h
GB
EOT
04h
04h
04h
04h
04h
04h
04h
04h
04h
04h
04h
04h
04h
04h
9

Publicité

loading

Ce manuel est également adapté pour:

21.2780