2.7) Markings
Cutting head, flexible insulated hose and pump must be provided with wording which enables both
clear identification and the correct correlation of cable cutting unit components.
?
The marking
up to 60 kV.
Permissible Operating pressure: 625 bar
The pressure of 625 bar is not exceeded in the use of the cable cutting units.
On the cutting head
Maximum diameter of the cable permissible: 85 mm, 95 mm, 120 mm (according to type; see
technical data).
Cables with external diameters up to the indicated values can be cut regularly.
On the flexible insulated hose
Repeated every 50 cm:
type of flexible insula-
ted hose
hose
manufacturer
®
EATON SYNFLEX
3VE0-03
On the guards hose:
–
(guard hose manufacturers mark)
– 10 / 30465 (manufactured year / laboratory test nr.)
– Q.C. AVR.10 (quality control; manufactured date month. year)
– 630 bar (permissible operating pressure)
–
60 kV (equipment suitable for working on cables under voltage up to 60 kV)
7
60000 V indicates that the device is suitable for use on cables with voltage
rated
diameter
3/16" I.D.
W.P. 10000 P.S.I. (690 BAR)
Max.
quarter and year
pressure
manufactured
in PSI
and BAR
(4Q09)
serial Nr.
NON CONDUCTIVE
144388