Télécharger Imprimer la page

Cembre CP1086-W-1000-KV Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.7) Markings
Cutting head, flexible insulated hose and pump must be provided with wording which enables both
clear identification and the correct correlation of cable cutting unit components.
?
The marking
up to 60 kV.
Permissible Operating pressure: 625 bar
The pressure of 625 bar is not exceeded in the use of the cable cutting units.
On the cutting head
Maximum diameter of the cable permissible: 85 mm, 95 mm, 120 mm (according to type; see
technical data).
Cables with external diameters up to the indicated values can be cut regularly.
On the flexible insulated hose
Repeated every 50 cm:
type of flexible insula-
ted hose
hose
manufacturer
®
EATON SYNFLEX
3VE0-03
On the guards hose:
(guard hose manufacturers mark)
– 10 / 30465 (manufactured year / laboratory test nr.)
– Q.C. AVR.10 (quality control; manufactured date month. year)
– 630 bar (permissible operating pressure)
60 kV (equipment suitable for working on cables under voltage up to 60 kV)
7
60000 V indicates that the device is suitable for use on cables with voltage
rated
diameter
3/16" I.D.
W.P. 10000 P.S.I. (690 BAR)
Max.
quarter and year
pressure
manufactured
in PSI
and BAR
(4Q09)
serial Nr.
NON CONDUCTIVE
144388

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

Cp1096-w-1000-kvCp1120-w-1000-kv