Logic
Defnition
Confguration of
EXPI1 input on
input-output ex-
EXPI1
pansion board.
1-2
Confguration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Confguration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Confguration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
TRAFFIC
Trafc light pre-
LIGHT PRE-
fashing
FLASHING.
TRAFFIC
LIGHT RED
Steadily lit red
light
LAMP
ALWAYS
ON
INSTALLATION MANUAL
Cross
De-
out
fault
setting
used
0
Input confgured as Start E command.
1
Input confgured as Start I command.
2
Input confgured as Open command.
3
Input confgured as Close command.
4
Input confgured as Ped command.
5
Input confgured as Timer command.
6
Input confgured as Timer Pedestrian command.
7
Input confgured as Phot (photocell) safety.
8
Input confgured as Phot op safety (photocell active during opening only).
1
9
Input confgured as Phot cl safety (photocell active during closing only).
10
Input confgured as Bar safety (safety edge).
Input confgured as Phot test safety (tested photocell).
11
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input,
EXPFAULT1.
Input confgured as Phot op test safety (tested photocell active during opening only).
12
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input,
EXPFAULT1.
Input confgured as Phot cl test safety (tested photocell active during closing only).
13
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input confgured as Bar safety (tested safety edge).
14
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
0
Input confgured as Start E command.
1
Input confgured as Start I command.
2
Input confgured as Open command.
3
Input confgured as Close command.
4
Input confgured as Ped command.
0
5
Input confgured as Timer command.
6
Input confgured as Timer Pedestrian command.
7
Input confgured as Phot (photocell) safety.
8
Input confgured as Phot op safety (photocell active during opening only).
9
Input confgured as Phot cl safety (photocell active during closing only).
10
Input confgured as Bar safety (safety edge).
0
Output confgured as 2
1
Output confgured as SCA (gate open light).
11
2
Output confgured as Courtesy Light command.
3
Output confgured as Zone Light command.
4
Output confgured as Stair Light.
5
Output confgured as Alarm.
6
Output confgured as Flashing light.
7
Output confgured as Latch.
11
8
Output confgured as Magnetic lock.
9
Output confgured as Maintenance.
Output confgured as Flashing Light and Maintenance.
10
11
Output confgured as Trafc Light control with TLB board.
0
Pre-fashing switched of.
0
1
Red lights fash, for 3 seconds, at start of operation.
0
Red lights of when gate closed.
0
Red lights on when gate closed.
1
Optional extras
nd
Radio Channel.
DEIMOS ULTRA BT A 400 - DEIMOS ULTRA BT A 600 -