12. Troubleshooting
Fault
The motor fails to
a) The capacitor is defective
start
b) There is no electricity at the plug
c) The cable is defective
d) The combined switch/plug is de-
fective
e) The connectors have become
separated from the motor or the
capacitor
f) The mower is standing in high
grass
g) The mower housing is clogged
The motor perfor-
a) The grass is too high or too damp
mance drops
b) The mower housing is clogged
c) The blade is severely worn
Cutting is irregular
a) The blade is worn
b) Wrong cutting height
Anleitung_RG-EM_1843_HW.indb 27
Anleitung_RG-EM_1843_HW.indb 27
GB
Possible causes
a) The mower housing is clogged.
b) Check the cable and the fuse
c) Check the cable
d) Have repaired by the Customer
e) Have repaired by the Customer
f) Start in low grass or on an area
g) Clean the housing so that the blade
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
a) Replace or resharpen the blade
b) Correct the cutting height
- 27 -
Remedies
Have repaired by the Customer
Service Center
Service Center
Service Center
that has already been mowed;
change the cutting height if neces-
sary
moves freely
14.10.11 09:41
14.10.11 09:41