At this point you will have to check the mechanical components inside
the barrier. The tie rod (fig. 11) is connected to the lever of the geared
reduction motor by means of the Ø12 mm pin "B1" which is welded
to the lever.
The distance between the pin "B1" and the tie rod "C1" is vital
for the correct functioning of the barrier. The minimum setting is
from 10-15 mm. In fact the pin "B1" must never intervene during
normal operation. It is security device designed to protect the
barrier from incorrect manual manoeuvres. If the mechanical
stop a point "B1" crashes against the tie rod damage will be
caused to the barrier.
4) Adjust the setting screw "X" (fig.10) and carry out the controls
described in point 3 until you have found its final position. Fasten
down using the relative lock nut.
5) Adjust the position of the rubber buffer "Y" so that the boom com-
mand lever "D1" doesn't crush it by more than 1-2 mm.
ELECTRONIC PROGRAMMER
Electronic programmer for a dc motor with an incorporated radio receiver card,which allows the memorisation of 300 user codes (see "remote control"
page 24). The "rolling code" type decoder uses 433.92 MHz. series transmitters.
ELECTRONIC CARD DSCRIPTION
B1
Remote code memorisation buzzer
CSER
Serial line connection
CB_1
Connection to binding post 1 on the battery charger
CB_5
Connection to binding post 5 on the battery charger
D1
6-digit Led display
DS1
Selection Dip-switch
ECB
External control buttons
F1
15A blade fuse
(2)
(protecting the motor power supply)
F2
3.15A rapid action fuse (protecting the 230Vac power supply)
F3
4A blade fuse
(2)
(protecting the 24V power supply)
J1
Radio channel selection jumper
J2
Remote code transmitter memorisation jumper
J3
Alarm mode selection jumper (controlling the speed of the boom)
L1
Power on LED
L2
Alarm mode indicator LED (controlling the speed of the boom)
L3
Transmitter code programming LED
L4
Blocking button indicator LED (TB)
L5
Travel direction inversion photocell indicator LED (FTCI)
L6
Contact safety buffer indicator LED (CSP)
L7
Opening direction deceleration travel limit indicator LED (FRA)
L8
Closing direction deceleration travel limit indicator LED (FRC)
L9
Opening travel limit indicator LED (FCA)
L10
Closing travel limit indicator LED (FCC)
L11
Opening button 1 indicator LED (TA1)
L12
Closing button 1 indicator LED (TC1)
L13
Opening contact 2 indicator LED (TA2)
L14
Closing contact 2 indicator LED (TC2)
M1
Memory module
Motor+ Motor Faston connection (positive)
Motor- Motor Faston connection (negative)
P1
Transmitter code memorisation button (MEMO)
P2
Transmitter code cancellation button (DEL)
P3
Programming button (PROG)
R1,R2
Motor activation relay
R3
Speed control relay
RF
433 MHz radio frequency module for S449 series transmitters
S1
Boom length selection 3 meters - 4 meters
V0
Secondary Faston connection 0Vac (blue)
V1
Secondary Faston connection 9,5Vac (brown)
V2
Secondary Faston connection 19Vac (yellow)
V3
Secondary Faston connection 28Vac (red)
V4
Secondary Faston connection 0Vac (grey)
V5
Secondary Faston connection 24Vac (grey)
Note
: If a battery charger isn't fitted, CB_1 must be bridged with
(1)
Note
: these are automotive type blade fuse (max. voltage 58V)
(2)
Note
: if the boom speed control relay "R3" is malfunctioning the following
(3)
will occur:
- if the jumper is closed nothing happens;
- if the jumper is open, LED "L2" lights up and the KLX output will
activate for 1 second each time the boom opens completely.
MANUAL MANOEUVRE (fig.14)
Attention! Releasing the gate should only be carried out when the motor
has stopped because of blackouts.
Open the front panel "F" to access the release mechanism and use the
special key supplied with the appliance.
Opening the access door will block the barrier and disactivate all the
functions. You are always advised however to shut off the power at the
mains before accessing internal components.
Release the emergency handle "G" (depending on the model) located
inside the door and insert the hexagonal end into the opening on the
motor.
Rotate the handle:
- clockwise to open;
- anticlockwise to close.
All rights reserved. Unauthorised copying or use of the information contained in this document is punishab
(1)
19
(1)
(3)
M1
DS1
CB_5
20
Selezione canali
Channel selection
Sélection canal
Kanalwahl
Selección
A
C H
C H
M1
36 35
B1
RF
RF MODULE 433 MHz
J2
J3
J3
R1
R2
S1
L1
R3
CH 1
Comando sequenziale
Sequential command
Commande séquentiel
Sequenziell Steuerung
Mando secuencia
B
C
C H
D
C H
FCC
D1
FCA
ECB
COM
CSP
FTC_I
COM
FRC
FRA
COM
TB
COM
TC2
TC1
COM
TA2
TA1
GND
CTR24Vac
KLX
LP
OUT 30Vdc
GND
AUX2
AUX1
EMRG
TRF 230Vac
230Vac
N
L