Access Secondary Parameter En; Special Functions - LORCH HandyTIG 180 DC ControlPro Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 156
Starting up HandyTIG 180 DC ControlPro
Job saving
 Set the welding machine as required.
 Press key pad „1" 31 or „2" 29 for at least 3 sec-
onds.
9 LED 28 or LED 30 will light up twice to confirm.
Job selection
 Shortly press key „1" 31 or „2" 29.
9 LED 28 or LED 30 will light up permanently to confirm
the selected job.
Job exit
 Turn knob 27 or press key 25 or 26 shortly.
14.4

Access secondary parameter en

 Press keys „1" 31 and „2" 29 shortly at the time.
9 The 7-segment-display shows alternating the param-
eter-code and the corresponding adjustment value.
 The adjustment value can be set by turning knob 27.
 By pressing key „1" 31 or „2" 29, the previous or sub-
sequent secondary parameter will be displayed.
‰ Depending on selected mode and function, different
secondary parameter are available.
Parameter
Gas pre-flow time
Start current
Start current time
Hotstart
Hotstart time
Upslope
Second current I
2
(% of welding
current I1)
Pulse frequency
Pulse switch
frequency
(% part of weld-
ing current I1)
Downslope
Final current
Final current time
10.15
Mode
0,1 s
0,1...10 s
x
50 %
5...200 %
x
0,1 s
0,0...20 s
x
125 % 5...200 %
x
1,0 s
0,0...20 s
x
5 %
0...99 %
x
50 %
1...200 %
x
x
0,2...500
5,0 Hz
x
x
Hz
50 %
1...99 %
x
x
20 %
0...99 %
x
25 %
5...200 %
x
0,2 s
0...20 s
x
Parameter
Gas post-flow time
(in % depending on
welding current) at
100% correspond-
ingly
3 A --> 2 sec.
50 A --> 3,5 sec.
100 A --> 5,1 sec.
140 A --> 6,4 sec.
180 A --> 7,7 sec.
HF-ignition
Tab. 3:
Secondary parameters ControlPro
 Press keys „1" 31 and „2" 29 shortly and at the same
time to exit the secondary parameter.
14.5

Special functions

Gas test, control panel test
 Press keys 25 and 26 at the same time and for at
least 2 seconds.
9 For about 30 seconds the gas valve will interconnect,
all operation displays will light up and the 7-segment
display 15 displays „GAS".
‰ Gas and operation test can be stopped by pressing
key 25.
x
Software-Version
 Press keys 26 and 29 at the same time and for least
x
1 second.
9 Software-Version of operation panel and main board
will be displayed.(i.e. dsp 2.3, St 1.1).
Master reset
Attention! All personal settings will be
i
x
lost.
All welding and secondary parameters are
reset to their factory settings (master reset
x
function).
 Press keys 25 and 31 at the same time and for at
x
least 5 seconds.
9 The 7-segment-display and all operation displays
LED 28 or LED 30 will light up shortly to confirm.
x
x
x
Mode
100 % 20...500 %
x
OFF
OFF...On
x
x