9. What if there are problems?
Problem
No LED display
Red LED
No mist is produced
The mist has a strange
smell
Strange noise
Strange noise
Mist escapes underneath
the water tank
10. Technical data
Dimensions (LxWxH)
Cable length
Weight when empty
Mains voltage/frequency
Nominal power
Room size
Capacity
Evaporation output
Signs and symbols
Cause
The mains cable is not plugged
in.
The control dial is at its minimum
position.
The water level is too low; the
water tank is empty.
The LED lights up green.
The LED lights up red.
The LED display does not light
up.
The device is new.
Stale or dirty water.
The water tank is not positioned
correctly on the base unit.
There is too little water in the
water tank.
The device is not level and un-
stable.
The water tank is not positioned
correctly on the base unit.
approx. 25 cm x 12 cm x 34 cm
approx. 1.5 m
approx. 1.5 kg
100 – 240 V AC / 50/60 Hz
20 watts
up to 25 m²
approx. 2.8 litres
220 ml/hour
The unit is double-protected and thus corresponds to protection
class 2.
Solution
Connect the plug.
Turn the control dial clockwise towards the
maximum position.
Fill the water tank.
Turn the control dial clockwise towards the
maximum position.
Fill the water tank.
Connect the plug.
Remove the water tank, turn the screwed
plug and remove it.
Air the open, emply water tank in a cool,
dry place for twelve hours.
Empty the base unit and the water tank and
clean them thoroughly.
Fill the water tank with fresh water.
Lift up the water tank and position it cor-
rectly on the base unit.
The tank should sit tightly on the base unit.
Fill the water tank.
Place the device on a firm, level surface.
Lift up the water tank.
Check whether the join between the base
unit and water tank is clean.
Clean if required.
Position the water tank correctly on the
base unit.
The tank should sit tightly on the base unit.
18